Special functions

Improving the quality of indoor air is one of the purposes of an air conditioner. This air
conditioner is equipped with ionizer or Plasma Dust Collector(Depending on specific
configuration of the model). With the anions generated by Ionizer, the air circulation 
of the air conditioner fills the room with refreshing, natural and healthy air. The Plasma
Dust Collector generates a high voltage ionization zone, through which the air is 
converted to plasma. Inside the air most of the dust, smoke, and pollen particles are
captured by the electrostatic filter.
 

CLEAN AIR function(on  some  models)

Function used after the shut down of cooling operation to clean the Evaporator 
,it keeps the air fresh for the next operation. 
For cooling models, the unit will operate under FAN ONLY  mode 
at LOW fan speed for half an hour, and then turn off automatically.
For cooling & heating models, the unit  will operate as in the below sequence : 
FAN ONLY mode at Low fan speed--Heating operation with LOW fan speed
---FAN ONLY operation--Stop Operation---Turn off. 

Note:

 

This function is only available under COOL(AUTO COOL, FORCED COOL) and 
DRY mode. 
Before selecting  the function, it is recommended to run the air conditioner under 
cooling operation for about half an hour. Once the Self Clean function is activated, 
all TIMER setting will be cancelled.
During SELF CLEAN  operation, when pressing the SELF CLEAN  button on the remote
controller again,the unit will stop the operation and turn off the unit automatically.

SELF CLEAN  function(Optional)

Refrigerant Leakage Detection 

With this new technology, the dipsplay area will appear  EC   and the indication lamps 
continue flashing when the outdoor unit detects refrigerant leakage.

Anti-mildew function(Optional)

When turns off the unit  on COOL, DRY, AUTO (Cool) mode, the air conditioner will continue 
operating for about 10 minutes (depending on models) with soft wind.This will help to
dry up the condensed water inside the evaporator, and prevent the breeding of mildew.
Under Anti-mildew operation, do not restart the air conditioner until the unit iscompletely off.
 

,

,

Louver Angle Memory Function(optional): 

Within the scope of safety angle, it will memorize the open angle of horizontal louver. 
If it exceeds, it will memorize the boundry of safety angle. In the following 
circumstances, it will return to standard angle: 1) pressing the turbo or manual control 
button, 2)unplug and then plug in the machine. 

So we strongly suggest that the open angle 

of the horizontal louver should not be set too small, in case the condensed water forms and 
drops from the horizontal louver.

Содержание ETERNA

Страница 1: ...Split Type Room Air Conditioner...

Страница 2: ...onnel only Installation work must be performed in accordance with the national wiring standards by authorized personnel only CAUTION 1 SAFETY PRECAUTIONS NAMES OF PARTS OPERATING INSTRUCTIONS CARE AND...

Страница 3: ...partner if it requires Never pull the plug out by pulling on the cable Hold the plug firmly and pull it out of the plug socket otherwise there is a risk of damaging the cable Do not operate your air...

Страница 4: ...o long with the doors or windows open or if the humidity is very high If the air conditioner is to be used in conjunction with other heaters the air should be refreshed periodically otherwise there is...

Страница 5: ...imer operation DEFROST indication lamp Enabled on cooling heating models only Lights up when the air conditioner starts defrosting automatically or when the warm air control feature is activated in he...

Страница 6: ...un the air conditioner under cooling operation for about half an hour Once the Self Clean function is activated all TIMER setting will be cancelled During SELF CLEAN operation when pressing the SELF C...

Страница 7: ...0 30 32 86 7 24 20 76 18 43 64 109 7 43 20 109 For the models with low temperature cooling system 18 52 64 126 For special tropical models 10 32 50 90 For special tropical models 11 43 52 109 18 52 6...

Страница 8: ...lease refer to the REMOTE CONTROLLER OPERATION MANUAL for details Range Range Deflector rod Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or d...

Страница 9: ...hours then hold steadily for the next 5 hours after that it will switch off This mode saves you energy and brings you comfort at night DRYING operation The temperature is regulated while dehumidifying...

Страница 10: ...oft dry cloth only If the unit is very dirty wipe it with a cloth soaked in warm water Cleaning the air filter and air freshening filter A clogged air filter reduces the cooling efficiency of this uni...

Страница 11: ...ot touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges Do not use water to clean inside the air conditioner Exposure to water can destroy the...

Страница 12: ...ive humidity A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting 3 Low noise of the air conditioner Yo...

Страница 13: ...re If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 10 Auto restart function Power failure during operation will stop the unit co...

Страница 14: ...it Wait Inappropriate temperature setting Air filter is blocked Doors or Windows are open Air inlet or outlet of indoor or outdoor unit has been blocked Compressor 3 or 4 minutes protection has been a...

Страница 15: ...E WASTE MANAGEMENT GUIDELINES 14 MIDEA...

Страница 16: ...o keep our commitments and to ensure best product performance We offer to you exciting Happy Homes Annual Maintenance plans to cover the service support for your products We recommend that you avail H...

Страница 17: ...16...

Страница 18: ...17...

Страница 19: ...18...

Страница 20: ...purchase However to avail the free services customer has to register for the same with our Customer care on 180030000011 stating the date of invoice and the dealers name from where the product has be...

Страница 21: ...Midea copy Customer copy Carrier Midea India Private Ltd Carrier Midea India Private Ltd 20...

Страница 22: ...21...

Страница 23: ......

Страница 24: ...Gurgaon 0124 6144300 FLAIR FLAIR X ETERNA...

Отзывы: