SAFETY  PRECAUTIONS

2

To prevent injury to the user or other people and property damage, the following  instructions 
must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
The seriousness is classified by the following indications.

This symbol indicates the possibility of death or serious injury.

Meanings of symbols used in this manual are as shown below.

WARNING

Be sure to follow the instructions.

Strictly prohibited.

CAUTION

This symbol indicates the possibility of injury or damage to property.

   Do not extend the cable and never use 
   multiple plugs. A poor electrical connection,
   poor insulation or voltage which is higher 
   than permitted can cause fire. 
   Do not expose your body directly to the cool
   air for prolonged period.
   Never poke fingers, sticks or other objects
   in the air inlet and outlet vents.
   Never attempt to repair, relocate, modify the
   air conditioner yourself. Always contact your
   service partner if it requires.
   Never pull the plug out by pulling on the 
   cable. Hold the plug firmly and pull it out of
   the plug socket, otherwise there is a risk of
   damaging the cable.
   

Do not operate your air conditioner in a wet 

   room such as a bathroom or laundry room.

   
 

   Remove all dirt from the power plug and 
   plug it firmly. Soiled plugs can cause fire
   or an electric shock.
   In the event of any abnormalities such
   as smell of burning, immediately swithch
   off the device and pull the plug. Contact
   your service partner.
   Always switch off the device and pull the
   plug before you start to clean it.
  Use specified power cord.
  

Contact the authorized  installer for 

  installation of this unit. 
  Contact an authorized service technician 
  for repair or maintenance of this unit.
  This appliance is not intended for use by 
  persons(including children) with reduced 
  physical, sensory or mental capabilities, or 
  lack of experience and knowledge, unless 
  they have been given supervision or 
  instruction concerning use of the appliance 
  by a person responsible for their safety. 
  Children should be supervised to ensure 
  that they do not play with the air  
  conditioner.
  

  
   
 

WARNING

Содержание ETERNA

Страница 1: ...Split Type Room Air Conditioner...

Страница 2: ...onnel only Installation work must be performed in accordance with the national wiring standards by authorized personnel only CAUTION 1 SAFETY PRECAUTIONS NAMES OF PARTS OPERATING INSTRUCTIONS CARE AND...

Страница 3: ...partner if it requires Never pull the plug out by pulling on the cable Hold the plug firmly and pull it out of the plug socket otherwise there is a risk of damaging the cable Do not operate your air...

Страница 4: ...o long with the doors or windows open or if the humidity is very high If the air conditioner is to be used in conjunction with other heaters the air should be refreshed periodically otherwise there is...

Страница 5: ...imer operation DEFROST indication lamp Enabled on cooling heating models only Lights up when the air conditioner starts defrosting automatically or when the warm air control feature is activated in he...

Страница 6: ...un the air conditioner under cooling operation for about half an hour Once the Self Clean function is activated all TIMER setting will be cancelled During SELF CLEAN operation when pressing the SELF C...

Страница 7: ...0 30 32 86 7 24 20 76 18 43 64 109 7 43 20 109 For the models with low temperature cooling system 18 52 64 126 For special tropical models 10 32 50 90 For special tropical models 11 43 52 109 18 52 6...

Страница 8: ...lease refer to the REMOTE CONTROLLER OPERATION MANUAL for details Range Range Deflector rod Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or d...

Страница 9: ...hours then hold steadily for the next 5 hours after that it will switch off This mode saves you energy and brings you comfort at night DRYING operation The temperature is regulated while dehumidifying...

Страница 10: ...oft dry cloth only If the unit is very dirty wipe it with a cloth soaked in warm water Cleaning the air filter and air freshening filter A clogged air filter reduces the cooling efficiency of this uni...

Страница 11: ...ot touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges Do not use water to clean inside the air conditioner Exposure to water can destroy the...

Страница 12: ...ive humidity A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting 3 Low noise of the air conditioner Yo...

Страница 13: ...re If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 10 Auto restart function Power failure during operation will stop the unit co...

Страница 14: ...it Wait Inappropriate temperature setting Air filter is blocked Doors or Windows are open Air inlet or outlet of indoor or outdoor unit has been blocked Compressor 3 or 4 minutes protection has been a...

Страница 15: ...E WASTE MANAGEMENT GUIDELINES 14 MIDEA...

Страница 16: ...o keep our commitments and to ensure best product performance We offer to you exciting Happy Homes Annual Maintenance plans to cover the service support for your products We recommend that you avail H...

Страница 17: ...16...

Страница 18: ...17...

Страница 19: ...18...

Страница 20: ...purchase However to avail the free services customer has to register for the same with our Customer care on 180030000011 stating the date of invoice and the dealers name from where the product has be...

Страница 21: ...Midea copy Customer copy Carrier Midea India Private Ltd Carrier Midea India Private Ltd 20...

Страница 22: ...21...

Страница 23: ......

Страница 24: ...Gurgaon 0124 6144300 FLAIR FLAIR X ETERNA...

Отзывы: