This water heater is for household, and it can be installed wherever place that need hot water.

Plug is not used for this water heater; this water heater must be connected directly with power 

switch that comes with leakage-protection. Please distinguish live line (red/brown), neutral line 

(blue) and earth line (green/yellow) during installation. 

Do check whether the amperes of the household wiring enough before installation, and 

dedicated circuit must be used when installation.

Before installing this water heater, check and confirm the earth electrode on the socket is reliably 

earthed, without electricity.

The hot water from the water heater may cause scald, please test the temperature of the hot 

water before use.

The distance between water heater installed and water output should be as nearby as possible 

to avoid loss of heat.

The electric water heater may be damaged if the water hardness is too high. To ensure longer 

product lifespan, please install and put it into use on condition that the local water hardness is 

less than 450mg/L (CaCO3)

In time of lightning/thunder, switch “Off” the Miniature Circuit Breaker (MCB) in advance to 

protect the water heater against possible damage.

Inspection on the built-in ELCB (once a month) to avoid a hazard to users such as damage to 

property, serious injury or death.

Do cut-off power supply before any maintenance. Any maintenance or adjustment towards this 

product by non-professional is highly prohibited.

The damage power cord must be replaced by a good power cord provided by the manufacturer, 

and the replacement should be done by a qualified technician or   engineer  or  professionals  of 

the similar products.

In order to avoid a hazard due to inadvertent resetting of the Earth Leakage Circuit Breaker 

(ELCB), this appliance must not be supplied through an external switching device, such as timer 

or connected to a circuit that is regularly switched “On” and “Off” by the utility.

Water heater is equipped with adjustable flow capacity safety valve. For safety use, please do 

not change its installation location and do not block its water outlet.

For any improper installation and incorrect operation of this product, our company will not be 

liable for any responsibility.

This water heater can be used for other purpose, eg. Washing hands, dishes or foods, and so on. 

(Multi directional water supply is not available).

When the shower is used by someone such as child, old person, sick person and physical 

handicapped person, the concern person is kindly requested to pay attention and check the 

shower temperature by using hand from time to time.

To prevent personal injury, injury to others and property damage, the instructions below must be 

followed. Incorrect operation due to failure to follow instructions will cause harm or damage.

Special Cautions

1. CAUTIONS

Содержание DSK45V

Страница 1: ...g and operating your water heater please read this manual carefully and keep it for future reference The diagram above is just for reference Please take the appearance of the actual product as the sta...

Страница 2: ...e 9 6 Troubleshooting 10 Sincerely thank you for selecting our electric water heater Please read this manual carefully before use correctly grasp the methods for installation and use of this electrica...

Страница 3: ...y or death Do cut off power supply before any maintenance Any maintenance or adjustment towards this product by non professional is highly prohibited The damage power cord must be replaced by a good p...

Страница 4: ...CT INTRODUCTION Model Rated Voltage Rated Frequency Rated Power Rated Current Dia Of Wire Code Air Switch Rated Pressure Minimum Flow Rate Minimum Pressure Maximum Pressure Protection Class Water Proo...

Страница 5: ...Silicon Control Main Control Board Relay Relay Flow Sensor Temperature Sensor Terminal Block G CN1 CN4 CN6 CN2 CN3 CN5 T1 T2 ELCB Terminal block Indicator light board Main control board Silicon contro...

Страница 6: ...ain Switch Knob and Power Knob to make it free Remove the front plate gently Gash the middle of the film of the power cord jacket with a sharp knife in order to put into power lines Tighten the wire p...

Страница 7: ...rive in the screws on the top and ensure certain distance between screw head and wall See Fig 1 Mount the unit on the wall and tighten with two screws at bottom connect the wires and install top cover...

Страница 8: ...r must be used when install the unit Blue marker stands for water inlet red marker stands for water outlet Do not overexert to avoid damaging the water heater NOTE A private power cord should be used...

Страница 9: ...y Leakage Protection When the electricity leakage testing circuit is working normally if the leakage current is bigger than certain value between 7 5mA and 15mA the indicator light will keep flickerin...

Страница 10: ...ist Please cut off the power in the weather of thunder and rain to avoid damaging the water heater If not use for long period of time please cut off water inlet to prolong the lifespan of the water he...

Страница 11: ...hermal cut out acts 4 Electricity leaks 1 Switch is off 2 Heating element error 3 PCB error 4 Water pressure is too low can t start the unit 1 The running water supply is cut off 2 The inlet valve of...

Страница 12: ...The product is subject to change without notice Please keep this manual properly...

Отзывы: