2.2 Parts Identification

WIRING DIAGRAM

2.3 Internal Wire Diagram

Indicator Light Board

Thermal 

Cut Out

Key Board

L

N
E

Red

Blue

Yellow/Green

Temperature 

Adjusting Board

Heating Elements

Silicon Control

Main Control Board

Relay

Relay

Flow Sensor

Temperature Sensor

Terminal Block

G

CN1

CN4

CN6

CN2

CN3

CN5

T1

T2

ELCB

Terminal block

Indicator light 

board

Main control board

Silicon control

Flow sensor

Marker for 

water inlet

Water inlet

Wire pressing board

Thermal 

cut out

Heating 

elements 

assembly

Stainless 

steel circlip

Marker for 

wateroutlet

Water outlet

Key board

Red

Blue

Содержание DSK45V

Страница 1: ...g and operating your water heater please read this manual carefully and keep it for future reference The diagram above is just for reference Please take the appearance of the actual product as the sta...

Страница 2: ...e 9 6 Troubleshooting 10 Sincerely thank you for selecting our electric water heater Please read this manual carefully before use correctly grasp the methods for installation and use of this electrica...

Страница 3: ...y or death Do cut off power supply before any maintenance Any maintenance or adjustment towards this product by non professional is highly prohibited The damage power cord must be replaced by a good p...

Страница 4: ...CT INTRODUCTION Model Rated Voltage Rated Frequency Rated Power Rated Current Dia Of Wire Code Air Switch Rated Pressure Minimum Flow Rate Minimum Pressure Maximum Pressure Protection Class Water Proo...

Страница 5: ...Silicon Control Main Control Board Relay Relay Flow Sensor Temperature Sensor Terminal Block G CN1 CN4 CN6 CN2 CN3 CN5 T1 T2 ELCB Terminal block Indicator light board Main control board Silicon contro...

Страница 6: ...ain Switch Knob and Power Knob to make it free Remove the front plate gently Gash the middle of the film of the power cord jacket with a sharp knife in order to put into power lines Tighten the wire p...

Страница 7: ...rive in the screws on the top and ensure certain distance between screw head and wall See Fig 1 Mount the unit on the wall and tighten with two screws at bottom connect the wires and install top cover...

Страница 8: ...r must be used when install the unit Blue marker stands for water inlet red marker stands for water outlet Do not overexert to avoid damaging the water heater NOTE A private power cord should be used...

Страница 9: ...y Leakage Protection When the electricity leakage testing circuit is working normally if the leakage current is bigger than certain value between 7 5mA and 15mA the indicator light will keep flickerin...

Страница 10: ...ist Please cut off the power in the weather of thunder and rain to avoid damaging the water heater If not use for long period of time please cut off water inlet to prolong the lifespan of the water he...

Страница 11: ...hermal cut out acts 4 Electricity leaks 1 Switch is off 2 Heating element error 3 PCB error 4 Water pressure is too low can t start the unit 1 The running water supply is cut off 2 The inlet valve of...

Страница 12: ...The product is subject to change without notice Please keep this manual properly...

Отзывы: