32801000801
13
Specifications subject to change without notice.
START−UP
Test Operation
Perform test operation after completing gas leak and electrical safety check. See the indoor unit installation instructions and owner’s manual for
additional start up information.
SYSTEM CHECKS
1. Conceal the tubing where possible.
2. Make sure that the drain tube slopes downward along its entire length.
3. Ensure all tubing and connections are properly insulated.
4. Fasten tubes to the outside wall, when possible.
5. Seal the hole through which the cables and tubing pass.
OUTDOOR UNIT
1. Are there unusual noises or vibrations during operation?
Explain the Following Items To Customer (with the aid of the Owner’s Manual):
1. Explain care and maintenance.
2. Present the installation instructions to customer.
TROUBLESHOOTING
For ease of service, the systems are equipped with diagnostic code display LEDs on both the indoor and outdoor units. The outdoor diagnostic display
is two LEDs (Red and Green) on the outdoor unit board and is limited to very few errors. The indoor diagnostic display is a combination of flashing
LEDs on the display panel or the front of the unit.
There may be a few error codes displayed in the indoor unit that might relate to the outdoor unit’s problems. If possible, always check the diagnostic
codes displayed on the indoor unit first.
The diagnostic codes displayed in the outdoor units are listed in Table 10.
Table 10—Outdoor Unit Diagnostic Guides
GREEN LED
RED LED
FAILURE MODE
On
X
Standby, normal
X
On
Operation, normal
On
On
High/Low voltage protection on compressor terminal
On
☆
EEPROM error
X
☆
The compressor speed is out of control
☆
On
Zero-crossing signal detection error; lack of phase; synchronization error
☆
X
IGBT or Module protection
☆
☆
Communication error
☆
= Flashing, X = Off
For additional diagnostic information, refer to the Service Manual