5.3 Pipe length and the elevation
The pipe length and refrigerant amount:
Model
Pipe size
Standard
length
(m)
Max.
Elevation
B (m)
Max.
Length
A (m)
Additional
refrigerant
(g/m)
Gas Liquid
MSABA-07HRN1-QC2+
MOAB30-07HN1-QC2
3/8’’
(
Ф
9.52)
1/4’’
(
Ф
6.35)
5 8
20
20
MSABA-09HRN1-QC2+
MOAB31-09HN1-QC2
3/8’’
(
Ф
9.52)
1/4’’
(
Ф
6.35)
5 8
20
20
MSABB-09ARN1-QB8+MOBA30-09HN1-QB8
3/8’’
(
Ф
9.52)
1/4’’
(
Ф
6.35)
5 8
20
20
MSABB-12HRN1-QC2 +MOBA30-12HN1-QC2
1/2’’
(
Ф
12.7)
1/4’’
(
Ф
6.35)
5 8
20
20
MSABB-12ARN1-QB6+MOBA30-12HN1-QB6
1/2’’
(
Ф
12.7)
1/4’’
(
Ф
6.35)
5 8
20
20
MSABD-18HRN1-QC2
+MOBA30-18HN1-QC2
1/2’’
(
Ф
12.7)
1/4’’
(
Ф
6.35)
5 10
25
20
MSABD-18ARN1-QB8
+MOCA30-18HN1-QB8
1/2’’
(
Ф
12.7)
1/4’’
(
Ф
6.35)
5 10
25
20
MSABE-24HRN1-QB8W +MOCA30-24HN1-QB8W
5/8’’
(
Ф
15.9)
3/8’’
(
Ф
9.52)
5 10
25
40
MSABE-24ARN1-QB8W +MOCA30-24HN1-QB8W
5/8’’
(
Ф
15.9)
3/8’’
(
Ф
9.52)
5 10
25
40
MSABF-36HRN1-RC0W +MOD30-36HN1-RC0W
5/8’’
(
Ф
15.9)
3/8’’
(
Ф
9.52)
5 15
30
40
Caution:
The capacity test is based on the standard length and the maximum permissive length is based on the
system reliability.
Содержание ABSEU-A4-1511
Страница 1: ...Aurora ON OFF SERIES Service Manual 2015 ABSEU A4 1511...
Страница 8: ...For MSABA 07HRN1 QC2 MSABB 09ARN1 QB8 MSABA 09HRN1 QC2...
Страница 10: ...For MSABF 36HRN1 RC0W...
Страница 12: ...For MOAB30 07HN1 QC2 MOAB31 09HN1 QC2...
Страница 14: ...For MOCA30 24HN1 QB8W MOCA30 18HN1 QB8 MOCA30 24HN1 QB8W...
Страница 15: ...For MOD30 36HN1 RC0W 946 W 810 H 1030 W1 673 A 403B 455D3 410 D 810 H 455 D3 15 57 H1 117 H2 73 12 24...