13. Troubleshooting
13.1 Indoor Unit Error Display
Display LED
STATUS
E0 EEPROM
error
E1
Indoor / outdoor units communication protection
E2 Zero-crossing
examination
error
E3
Fan speed beyond control
E5
Open or short circuit of outdoor temperature sensor
E6
Room temperature or evaporator temperature sensor open or short circuit of
P0 Module
protection
P1
Over voltage or too low voltage protection
P2
Compressor top protection against temperature
P3
Outdoor low temp. protection
P4
Inverter compressor drive error
Note: E4: Reserved function
13.1.1
Display LED
STATUS
E0
EEPROM parameter error
13.1.2 circuit or software error on indoor cortrol board
Display LED
STATUS
E1
Indoor / outdoor units communication protection
Replace the control board of indoor
Circuit or software error on indoor control board