4
1. Precaution
1.1. Safety Precaution
1. Do not modify this appliance. This appliance should be serviced by an authorized person.
2. All repairs should be done in accordance with the procedures described in this manual.
3. Before you begin, turn off the gas and electricity supply to the appliance. Remove
remaining gas in product completely by igniting burner.
4. Be sure that all of built-in protective devices are replaced. Restore any missing protective
shields.
5. Do not connect the gas and electricity supply before replacement complete.
6. Use replacement components that have the same ratings. A replacement part that does not
have the same safety characteristics as the original might create shock, fire or other
hazards
7. You must conduct a gas leakage test after receiving after-sales service in gas pipe and gas
connector. Never touch any circuit wiring with your hand nor with uninsulated tool during
operation.
1.2. Warning
1.
The power cord shall be replaced with the original power cord, specifications for an
insulation power line which is no less than AWG8*2 +AWG10*1 and resists
temperature of greater than 60
℃
.
2. All apparatus within a radius of 50mm from this product must resist temperature of
greater than 75°C, otherwise, deformations are easily to be caused during the
application process of this product.
3. When the wrapping materials are removed, keep such materials like metal sheet,
packing bag, foam and screws out of reach of children’s reach to avoid potential
dangers. For example, the children may suffocate as a result of swallowing tiny
components or playing with packing bag.
Содержание 60G SERIES
Страница 5: ...5 2 Description of the appliance 2 1 Features Glass Q502 GXX Stainless Q411 SXX...
Страница 6: ...6 2 2 Components and parts 1 Burner 2 Pan support 3 Knob 4 Drip tray...
Страница 10: ...10 4 Electric Diagram a Four burners model b Five burners model...
Страница 18: ...18 6 Troubleshooting 6 1 Troubleshooting...
Страница 19: ...19 6 2 Problems and Corrective Measures...
Страница 23: ...23 Comparison list for injector replacement Nominal heat input and rates see below at 15 at 1013mbar...