Service Manual
, 2016-12
25
/
45
Damper assembly
(None)
8.5
Evaporator and temperature sensing system
Evaporator in freezing chamber
1
)
Remove the air duct components in freezing chamber.
2
)
Disconnect all connectors.
3
)
Remove the welding on inlet and outlet tubes.
4
)
Remove two screws which are used to fix the
evaporator and remove the evaporator.
Components on the evaporator
Fuse
The fuse is located on top of the evaporator
1
)
connect the fuse connector.
2
)
Cut off the band which fixes the fuse.
3
)
Separate the fuse and the evaporator.
*,Don’t break the welding of the evaporator in case that
only the fuse needs to be replaced.
Содержание 22031020000113
Страница 5: ...Service Manual 2016 12 5 45 1 Safety Warning Code 1 1Warning for operation safety ...
Страница 6: ...Service Manual 2016 12 6 45 ...
Страница 7: ...Service Manual 2016 12 7 45 ...
Страница 8: ...Service Manual 2016 12 8 45 1 2Safety instruction for refrigerant ...
Страница 17: ...Service Manual 2016 12 17 45 5 5Circuit diagram ...
Страница 38: ...Service Manual 2016 12 38 45 11 2 Compressor failure ...
Страница 39: ...Service Manual 2016 12 39 45 11 3 Defrosting is not working ...
Страница 40: ...Service Manual 2016 12 40 45 11 4 Fan in the freezing chamber is abnormal Refer to this method for other fans ...