Service Manual
, 2016-12
31
/
47
9.4 Fault code and solutions
Fault
code
Fault
content
Display
Steps for maintenance methods
E2
Freezer
temperatur
e sensor fail
E2
Step 1: to check whether the CN4 wiring connector connect
well, unplug and plug in again;
Step2: to check whether there is foreign object on the wiring
connector of sensor, unplug the connector by refering to
chapter 8.5, and check the Ohmic value by comparing with the
resistance sheet
Step3: change the main PCB
Step4: Change the wiring harness
E5
Defrosting
sensor fail
E5
Step 1: to check whether the CN4 wiring connector connect
well, unplug and plug in again;
Step2: to check whether there is foreign object on the wiring
connector of sensor, unplug the connector by refering to
chapter 8.5, and check the Ohmic value by comparing with the
resistance sheet
Step3: change the main PCB
Step4: Change the wiring harness
E6
Ambient
temperatur
e sensor fail
E6
Step1: to check whether the whether the wiring harness
connected well
Step2:change the main PCB
Step3:change the display PCB
E7
F room high
temp alarm
E7
Step 1: to check whether the CN8 wiring connector connect
well, unplug and plug in again;
9.5Test mode
Press
and at the same time for 3s with a beep, enters into factory
mode, the default display is “0”.
Item#
Mode Name
Usage Scenarios
Purpose
Canceling
0
Mode
selecting
Exit
When the user enters the mode selecting
state, the default number is "0". If
the user selects non of the blow mode,
or select back to “0” mode. Lock it,
then the freezer will exit factory
mode, the display shows back the
temperature.
Using for exiting the
mode selecting if the
user enter the mode
selecting state.
(especially for
entering the mode
selecting by accident)
Can not be
canceled
AP
WiFi
connecting
rest
If the user changed their routers, or
the freezer was moved to another wifi
environment. They need to use it to
reconnect the freezer with the new
internet. At single wifi environment,
at this mode, the freezer will be
connected to it automatically. At
Using for wifi
reconnection.
Can not be
canceled
Содержание 22031010000841
Страница 5: ...Service Manual 2016 12 5 47 1 Safety Warning Code 1 1Warning for operation safety...
Страница 6: ...Service Manual 2016 12 6 47...
Страница 7: ...Service Manual 2016 12 7 47...
Страница 8: ...Service Manual 2016 12 8 47 1 2Safety instruction for refrigerant...
Страница 37: ...Service Manual 2016 12 37 47 11 Troubleshooting Method 11 1 No refrigeration...
Страница 38: ...Service Manual 2016 12 38 47 11 2 Compressor failure...
Страница 39: ...Service Manual 2016 12 39 47 11 3 Defrosting is not working...
Страница 40: ...Service Manual 2016 12 40 47 11 4 Fan in the freezing chamber is abnormal Refer to this method for other fans...
Страница 41: ...Service Manual 2016 12 41 47 11 5 Damper is abnormal None 11 6 Lights inside the refrigerator don t light up...