Service Manual
, 2016-12
35
/
47
10.4
Fan motor circuit of the freezing chamber
12 V voltage is reduced to 7~12V through the control chip BD9227F ,output it to F-FAN pin and
connect it to positive pole of fan, to control the operating of fan in different revolution. Check the
voltage between F-FAN pin and GDN pin, to estimate the fan trouble.
10.5
Refrigerator fan motor circuit (None)
10.6
Condensing fan motor circuit (None)
10.7
Damper motor circuit (None)
10.8
Resistance value of the sensor (R/T)
Tx(
℃
)
R
(
KΩ
)
Tx(
℃
)
R
(
KΩ
)
Tx(
℃
)
R
(
KΩ
)
Tx(
℃
)
R
(
KΩ
)
Tx(
℃
)
R
(
KΩ
)
-30
33.81
-15
14.31
0
6.495
15
3.141
30
1.617
-29
31.85
-14
13.55
1
6.175
16
2.999
31
1.55
-28
30.01
-13
12.83
2
5.873
17
2.865
32
1.486
-27
28.29
-12
12.16
3
5.587
18
2.737
33
1.426
-26
26.68
-11
11.52
4
5.315
19
2.616
34
1.368
-25
25.17
-10
10.92
5
5.06
20
2.501
35
1.312
-24
23.76
-9
10.35
6
4.818
21
2.391
36
1.259
-23
22.43
-8
9.82
7
4.589
22
2.287
37
1.209
-22
21.18
-7
9.316
8
4.372
23
2.188
38
1.161
-21
20.01
-6
8.841
9
4.167
24
2.094
39
1.115
Содержание 22031010000841
Страница 5: ...Service Manual 2016 12 5 47 1 Safety Warning Code 1 1Warning for operation safety...
Страница 6: ...Service Manual 2016 12 6 47...
Страница 7: ...Service Manual 2016 12 7 47...
Страница 8: ...Service Manual 2016 12 8 47 1 2Safety instruction for refrigerant...
Страница 37: ...Service Manual 2016 12 37 47 11 Troubleshooting Method 11 1 No refrigeration...
Страница 38: ...Service Manual 2016 12 38 47 11 2 Compressor failure...
Страница 39: ...Service Manual 2016 12 39 47 11 3 Defrosting is not working...
Страница 40: ...Service Manual 2016 12 40 47 11 4 Fan in the freezing chamber is abnormal Refer to this method for other fans...
Страница 41: ...Service Manual 2016 12 41 47 11 5 Damper is abnormal None 11 6 Lights inside the refrigerator don t light up...