SECTION 3
OPERATION
26
Control Panel
IV. STEP-BY-STEP OPERATION
A. Daily Start-up Procedure
1. Check that the circuit breaker/fused disconnect is
in the on (closed) position.
2. Turn the BLOWER switch to the
“ON” or “I” position. This starts the
main blower fan and the cooling
fans. The blower circulates air
through the air fingers and must
stay on during the cooking or
baking process.
3. Check to see if the cooling fans, located at the rear
of the oven (see Figure 7 in Section 1), are
operating when the blower switch is turned “ON”
or “I”. The cooling fans cool the control
components and blower motor by blowing air into
and through the cabinet. Air travels to the front of
the cabinet and out the front of the oven. Refer to
Daily Maintenance Section for the fan intake
checking procedure.
IMPORTANT
The cooling fan operates when the BLOWER switch
is turned “ON” or “I”. It must operate to keep the
control console below 140°F (60°C).
4. Turn the CONVEYOR switch
to the “ON” or “I” position.
This starts the conveyor belt
moving through the oven.
Содержание PS629E Series
Страница 10: ...SECTION 1 DESCRIPTION 10 NOTES...
Страница 18: ...SECTION 3 OPERATION 18 Model PS629E Dimensions with Optional Legs Casters...
Страница 22: ...SECTION 3 OPERATION 22 NOTES...
Страница 30: ...SECTION 3 OPERATION 30 NOTES...
Страница 37: ...SECTION 4 MAINTENANCE 37...
Страница 44: ...SECTION 4 MAINTENANCE 44...
Страница 48: ...SECTION 5 TROUBLESHOOTING 48 Wiring Diagram E230V 1PH CE PS629E 74665 REV F...
Страница 49: ...SECTION 6 ELECTRICAL SCHEMATICS 49 Wiring Diagram E380V 3PH PS629E 74667 REV F...
Страница 50: ...SECTION 5 TROUBLESHOOTING 50 Wiring Diagram E380V 3PH CE PS629E 74669 REV F...
Страница 51: ...SECTION 6 ELECTRICAL SCHEMATICS 51...