IMPORTANT SAFETY INSTRUCTIONS 

Page 3

When using electrical products, basic precautions should always be followed, including the following:

• 

Read and follow all instructions before using.

• 

There are no user-serviceable components within this device. Removal of the cover from this device may present a shock

 

hazard, and void the warranty.

• 

DANGER – To reduce the risk of electrical shock:

 

Always unplug this device from the electrical outlet before cleaning.

• 

WARNING – To reduce the risk of burns, fire, electric shock, or injury to persons:

1. 

Unplug from outlet before putting on or taking off parts.

2. 

Close supervision is necessary when this device is used by, or near children, invalids, or disabled persons.

3. 

Use this device only for its intended use as described in these instructions.  Do not use attachments not

 

recommended by the manufacturer.

4. 

Never operate the device if it has a damaged cord or plug, if it is not working properly, if it has been dropped or

 

damaged, or dropped into water. Return the device to a service center for examination and repair.

5. 

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point

 

where they exit from the apparatus.

6. 

Keep the cord away from heated surfaces.

7. 

Never drop or insert any object into any opening.

8. 

Do not use outdoors.

9. 

Do not operate where aerosol (spray) products are being used or where oxygen is being administered.

10.  To disconnect, turn all controls to the off position, then remove plug from outlet.

11.  WARNING: Risk of Electric Shock – Connect the device to a properly grounded outlet only.

 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one

 

wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third

 

prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement

 

of the obsolete outlet.

12.  WARNING: The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as

 

vases, shall be placed on the apparatus"

13.  The mains plug is used as your disconnect device.  This device shall remain readily operable.

14.  Clean only with dry cloth.

15.  Unplug this apparatus during lightning storms or when unused for long periods of time.

16.  Only use attachments/accessories specified by the manufacturer.

17.  Do not overload the wall outlet where this device is being connected. Do not overload this device. Ensure the total load

 

to this device does not exceed that which is listed in the specifications section of this manual.

18.   Ensure this device is connected to a properly grounded AC power source. Ensure the device is plugged into a source

 

providing the required 120V. Do not use a plug adapter that defeats the ground pin of the AC plug.

  SAVE ALL INSTRUCTIONS

Safety Instructions - Rack Mount

A. Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be 
greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient 
temperature (Tma) specified by the manufacturer.

B. Reduced Air Flow- Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not 
compromised.

C. Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical 
loading.

D. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the 
circuit might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when address-
ing this concern.

E. Reliable Earthing - Reliable earthing of rack-mounting equipment should be maintained. Particular attention should be given to supply connections 
other than direct connections to the branch circuit (e.g. use of power strips).

• Disconnect Device (Pluggable Equipment) - The socket-outlet shall be installed near the equipment and shall be easily accessible.

Содержание PD-DC-125R

Страница 1: ...asing the PD DC 125R PRODUCT FEATURES THANK YOU Multi voltage support 5 12 18 24V Surge and overload protection Adjustable mounting ears for flexible installation options Four 5V USB Charging Ports TOTAL 5V 2 5A ALL USB STATUS STATUS STATUS STATUS PD DC 125R ACTIVE OVERLOAD SHUTDOWN STATUS ...

Страница 2: ... to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with ...

Страница 3: ...ed to dripping or splashing and that no objects filled with liquids such as vases shall be placed on the apparatus 13 The mains plug is used as your disconnect device This device shall remain readily operable 14 Clean only with dry cloth 15 Unplug this apparatus during lightning storms or when unused for long periods of time 16 Only use attachments accessories specified by the manufacturer 17 Do n...

Страница 4: ...2 AVERTISSEMENT L appareil ne doit pas être exposé à des éclaboussures et aucun objet rempli de liquide comme des vases ne doit être placé sur l appareil 13 La fiche secteur est utilisée comme sectionneur de courant Ce dispositif doit rester en état de marche 14 Nettoyer uniquement avec un chiffon sec 15 Débrancher cet appareil pendant les orages ou s il n est pas utilisé pendant de longues périod...

Страница 5: ...ARDWARE KIT INCLUDES Orange 5V DC Connector Yellow 12V DC Connector Blue 18V DC Connector Red 24V DC Connector Standard Mount Ears Deep Rack Mount Ears Rack Ear Screws QTY DESCRIPTION 6 6 6 6 2 2 12 ITEM A B C D E F G A B C D G E F H ...

Страница 6: ... SIX OUTPUTS Individually protected by automatically resettable PTC Fuses Short circuit and overload protection F 24V DC 1 2A BANK SIX OUTPUTS Individually protected by automatically resettable PTC Fuses Short circuit and overload protection G BANK OVER CURRENT WARNING LIGHT Green OK Amber Approaching current limit of power bank shutdown imminent H IEC C 14 POWER INPUT 120VAC 5A 60HZ I OUTPUT POWE...

Страница 7: ...and negative wire ends 3 Select appropriate color coded terminal block A Orange 5V DC B Yellow 12V DC C Blue 18V DC D Red 24V DC 4 Insert bare wire ends into terminal block 5 Tighten connections securely with screwdriver 6 Insert terminal block into appropriate power bank 1 4 FIGURE A RACK EAR INSTALLATION 1 Install rack ears as shown using supplied rack ear screws FIGURE B 2 Rack ears may be inst...

Страница 8: ...OUNTING VERTICAL MOUNTING All ears can be mounted facing front or rear of unit Standard depth mount ears pictured Deep rack mount ears can be mounted facing front or rear of unit All ears can be mounted facing up or down front or rear of unit Standard depth mount ears pictured ...

Страница 9: ... 108VAC MAX 127VAC 5A AC 600W DC OUTPUTS FULLY LOADED IEC C 14 6 Feet MOV MODE L N CLAMPING VOLTAGE 595V 11 2A DC 125 3W Automatically Resetting PTC Fused On Each Output 250A AC VOLTAGE 5V DC 12V DC 18V DC 24V DC USB 5VDC MAX CURRENT TOTAL RAIL 3A 2A 2 5A 1 2A 2 5A MAX CURRENT PER OUTPUT RAIL CURRENT WARNING 2A 1 5A 1A 75 2 1A 2 85A 1 9A 2 25A 1 15A N A DC OUTPUTS CAUTION Do not exceed maximum rat...

Страница 10: ...OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW IN NO EVENT SHALL THE COMPANY BE LIABLE FOR ANY SPECIAL INCIDENTAL INDIRECT OR CONSEQUENTIAL DAMAGES WHATSOEVER INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION OR ANY...