Maintenance

Keep the area around the burner clear and free of combustible materials, gasoline and other
flammable liquids or vapors. Do not obstruct burner air inlet slots or ventilation grilles for com-
bustion air.

The motor features permanently lubricated ball bearings and requires no routine oiling mainte-

nance.

IMPORTANT:

Check the burner flame periodically. A proper NATURAL gas flame will appear blue

at the burner face with orange and yellow tips. A proper PROPANE gas flame will appear blue at
the burner face with yellow tips. If the flame is too rich, it will appear billowy and yellow with
hazy tips. If too lean, it will appear short and all blue. If the flame does not appear proper,

CON-

TACT A QUALIFIED SERVICE TECHNICIAN FOR CLEANING, READJUSTMENT AND/OR
REPAIR.

WARNING: If any flame is observed when the burner is on standby, or if

the ignition spark or valve operator is heard to come on before the motor
reaches operating speed, immediately turn off the Main Manual Shut-off
Valve and burner power. A dangerous condition has developed and must be
corrected. 

CONTACT A QUALIFIED SERVICE TECHNICIAN FOR CLEANING READJUST-

MENT AND/OR REPAIR.

WARNING: If PROPANE gas is used and the burner is located in a base-

ment, crawl space or confining space, contact your gas supplier about
installing a GAS LEAK warning device. PROPANE gas is heavier than air and
can settle in low areas or confined spaces. This would create a danger of
explosion or fire. If you suspect a gas leak, follow instructions on front cover
of this manual.

1.

SET OPERATING CONTROL TO 

OFF

OR THERMOSTAT BELOW ROOM TEMPERATURE FOR AT 

LEAST 30 SECONDS.

2.

TURN MANUAL GAS COCK KNOB ON COMBINATION VALVE TO 

ON

.

3.

TURN BURNER POWER ON.

4.

SET OPERATING CONTROL TO 

ON

OR THERMOSTAT TO CALL FOR HEAT (IN CANADA THERE

IS A 30 SECOND PREPURGE).

5.

WAIT 6 SECONDS. IF BURNER HAS FAILED TO LIGHT, OR IF BURNER LIGHTS THEN GOES OUT
AND SYSTEM GOES INTO SAFETY LOCKOUT, DE-ENERGIZE THE SYSTEM BY SETTING 
OPERATING CONTROL TO 

OFF

OR THERMOSTAT BELOW ROOM TEMPERATURE FOR AT 

LEAST 30 SECONDS TO RESET THE SYSTEM AND THEN SET OPERATING CONTROL TO 

ON

OR THERMOSTAT TO CALL FOR HEAT.

TO SHUT OFF

1.

TURN MANUAL GAS COCK KNOB ON COMBINATION VALVE TO 

OFF

.

2.

TURN BURNER POWER OFF.

SHOULD OVERHEATING OF THE GAS UTILIZATION EQUIPMENT OCCUR:

1.

Shut off the main manual shut-off gas valve to the equipment.

2.

Do not

shut off the power switch to the 

ECONOMITE

burner, or the equipment pump or 

blower.

9

Consumer Instructions

Lighting Instructions

Содержание Economite DS24A

Страница 1: ...ch hazards Affix this manual adjacent to the conversion burner CODE COMPLIANCE IS THE SOLE RESPONSIBILITY OF THE INSTALLER WARNING If the information in these instructions is not followed exactly a fi...

Страница 2: ...0 square inches of the total input rating of all gas utilization equipment in the confined space One grille should be located within 12 inches of the ceiling the other within 12 inches of the floor If...

Страница 3: ...zzle ribbon is free of for eign materials and also that the electrodes have not been damaged or displaced see Figure 7 WARNING The chimney shall be inspected for unsafe conditions such as deteriorat e...

Страница 4: ...e sure to hook up to a permanently live circuit Provide a fused on off disconnect switch carrying a minimum 3 amp fuse The frame of the burner must be well grounded A terminal is provided in the contr...

Страница 5: ...OPANE gas only and should be used only with the gas specified on rating plate A Standard Model DS24A Economite is shipped ready for NATURAL gas As shipped it is field convertible to PROPANE gas see Ta...

Страница 6: ...or capacity rating of the gas utilization equipment Refer to Section VII Main Gas Spud and Table 3 5 RESET the Electronic Control by setting the operating control to OFF or the thermostat below room t...

Страница 7: ...ng and shut off procedure refer to CONSUMER INSTRUCTIONS or to the instruction plate mounted on the burner DANGER Be sure that the Main Manual Shut Off Valve Combination Valve and Burner Power Switch...

Страница 8: ...stment an overfire condition could result when pressure returns to normal particularly if the regu lator adjustment screw is bottomed out ALWAYS confirm that at least the minimum rated gas pressure is...

Страница 9: ...OR REPAIR WARNING If PROPANE gas is used and the burner is located in a base ment crawl space or confining space contact your gas supplier about installing a GAS LEAK warning device PROPANE gas is hea...

Страница 10: ...ol b Between Electronic Control high voltage terminal and Spark Electrode Wire insert head of 8 x 3 4 or longer round head screw into snap terminal inside right angle rubber boot No spark broken wire...

Отзывы: