act
scene
Automation Central Control Section
Assign Keys And Mode Switches
The VCA FOH, VCA MON, GROUP and AUX switches set the current assignment/display
mode for the input module assign LEDs. As a default these switches interlock so that only one
mode can be viewed at a time, however if they are pressed down for more than 0.5 second the
interlock is removed. This is used for "clear mode" (see below).
If the VCA FOH and VCA MON MUTES have been selected for operation independent from the
VCAs ( in the SYSTEM menu) they can be selected by pressing the VCA switches for 3 seconds.
The ASSIGN KEYS are used to change settings for input
VCA FOH, VCA MON, audio group or aux assignment in
conjunction with the SET switch on each channel as
follows:-
To enter ASSIGNMENT mode first press the LOCK
switch (to un-lock the assignment system).
Press the ASSIGN KEYS to set up the required
group number or numbers; a long press will allow
multiple assignment where as a short press will clear
the previous settings.
Press the SET switch on the input channels to which
the assignment is required. Again there are two ways
to do this; a long press will remove all prior settings
on the input and replace them with the new
assignment; a short press will toggle the state of any
switches within the assignment set up. i.e. if assign
keys one and two are on. Pressing the input SET
switch will cause that channel to toggle the number
one and two assignments for the channel either from
off to on or visa versa.
To enter CLEAR mode set all the assign keys to off.
To do this simply press the ones that are illuminated
which will toggle them off.
In this mode operating an input SET switch with a
long press will clear all assignments. The mode
switches can be used to select which parts are
cleared, i.e. press VCA mode to clear VCA's, press
GROUP mode to clear group routing, or use a long
press to activate more modes for simultaneous
clearing.
27
aux /
check
mute
Group
store
a
b
active system
(hold 3secs)
lock
s-i-p
midi
system
delete copy
insert
check
confirm
cancel
now
down
next
act/scene
c/o
last
up
1
3
5
7
9
11
2
4
6
8
12
10
mon
mute
(hold
3secs)
(hold
3secs)
vca
mon
v.c.a./
Mute/
Содержание LEGEND 3000
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 18: ...8...
Страница 43: ...Automation System Control 33...
Страница 58: ...48...
Страница 59: ...Frame sizes and Dimensions 49...
Страница 61: ...51 Rear Panel Configuration...
Страница 62: ...Midas Legend 3000 Rear Panel 32 mono channel 52...
Страница 63: ...53...
Страница 64: ...54...
Страница 65: ...Edac Wiring Diagrams 55...
Страница 67: ...Block Diagrams 57...
Страница 77: ...Specification and Overview 67...
Страница 81: ...MIDAS L3750 Power Supply 71...
Страница 83: ...Input Crib Sheet Inputs to Input No Notes 73...
Страница 84: ......