![Mid-Continent Instrument True Blue Power TB20 Series Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/mid-continent-instrument/true-blue-power-tb20-series/true-blue-power-tb20-series_installation-manual-and-operating-instructions_1789980047.webp)
46
Manual Number 9019286 • Revision E, January 06, 2022
5.9 DO-311A COMPLIANCE QUALIFICATION FORM
MODEL NUMBER:
TB20
_
PART NUMBER:
6430020-( )
DESCRIPTION:
Advanced Li-Ion Main Ship Battery
CERTIFICATION:
FAA TSO-179b
MANUFACTURER:
True Blue Power, a division of Mid-Continent Instrument Co., Inc.
ADDRESS:
9400 E. 34
th
St. North, Wichita, KS 67226, USA
SPECIFICATION:
Test Specification (TS) 713 Test Data Sheet (TDS) 713
STANDARD
:
RTCA DO-311, Rev A, dated 12/19/2017
SECTION
SUB
TITLE
RESULT
SUMMARY
1
1.4
Battery Categories
Comply Energy Category 4: >200Wh
Venting Category B: designed vent
Architecture Category: Standalone
2
2.1
General Requirements
Comply RTCA/DO-178C, DAL A
Rated Capacity: 20Ah
2.2
Equipment Requirements
Comply
Met by passing tests in 2.4.4
2.3
Environmental Conditions
Pass
Required sections of RTCA/DO-160
complete; see EQF
2.4.4
Perform
an
ce
Test
s
2.4.4.1
Physical Examination
Pass
See IM for physical specifications
2.4.4.2
Acceptance Test Procedure
Pass
ATP per MPS identified above
2.4.4.3
Insulation Resistance
Pass
Contacts/case electrically connected
2.4.4.4
Handle Strength
Pass
Each handle capable of 2X unit weight
2.4.4.5
Capacity Test
Pass
20Ah minimum
2.4.4.6
Capacity Test at Low/High
Temp
Pass
16.5Ah @ -40°C; 19.5Ah @ 70°C
2.4.4.7
Constant Voltage Discharge
Pass
I
PP
= 900A, I
PR
= 700A @ 18V
2.4.4.8
Charge Acceptance
Pass
18Ah @ -40°C; 19Ah @ 23°C
2.4.4.9
Charge Retention
Pass
90% @ 23°C; 80% @ 50°C
2.4.4.10
Cycle Test
Pass
Retained 99% capacity @ 100 cycles
2.4.4.11
Rapid Discharge Test
Pass
I
MAX
= 160A @ 70°C
2.4.4.12
Short Circuit with Protection
Pass
Max current = 2980A; S/C cutoff @
124ms
2.4.4.13
Overdischarge Test
Pass
Protective circuitry prevented charging
after overdischarge
2.4.4.14
Overcharge Test
Pass
Overcharge protection activated at 31.5V
2.4.5
Safety
Tes
ts
2.4.5.1
Short Circuit Test of a Cell
Pass
No release of fragments, flames or
emissions
2.4.5.2
Short Circuit Test of a Battery
without Protection
Pass
No release of fragments, flames or
emissions
2.4.5.3
Overdischarge without
Protection
Pass
Emission of gas, smoke and electrolyte
exited vent port
2.4.5.4
Single Cell Thermal Runaway
Containment Test
N/A
2.4.5.5
Battery Thermal Runaway
Containment Test
Pass
All cells achieved thermal runaway;
Maximum case temp = 122°C
2.4.5.6
Explosion Containment
Pass
No ruptures in case; no emissions
observed
2.4.5.7
Drop Impact
N/A
REMARKS:
Compliance includes all of Section 1 and Section 2, unless noted.
Sub-paragraphs without specific criteria of note are not listed.
Содержание True Blue Power TB20 Series
Страница 1: ...Revision E January 6 2022...