Additional Precautions
The following design and operation factors are required for safe use.
It is not acceptable to combine or use any battery cells or modules other than those
approved by True Blue Power within this battery pack.
There are no limitations in storing or using this battery in the vicinity of other battery
chemistries. This battery does not emit or absorb any gas during storage, transportation
or during normal operating conditions.
Batteries must not be installed with the output terminals reversed. A reversed battery
could be charged by other batteries in the circuit during discharge; or discharged by the
charging system during charge.
Battery terminals must be covered with non-conductive protective devices to avoid any
possibility of shorting during handling, shipping or storage.
Shipping
True Blue Power lithium-ion cells and batteries are designed to comply with all applicable
shipping regulations as prescribed by industry and regulatory standards. This includes
compliance with the UN recommendations on the Transport of Dangerous Goods, IATA
Dangerous Goods Regulations, applicable U.S. DOT regulations for the safe transport of
lithium-ion batteries, and the International Maritime Dangerous Goods Code. In accordance
with IATA and per UN 3480, PI 965, Section 1A and 1B, when shipped by air, the True Blue
Power Advanced Lithium-ion Battery will be shipped with a state of charge (SOC) not to
exceed 30% of rated capacity. This battery is classified as a Class 9 Dangerous Goods. If the
battery requires shipment, please refer to Section 5.4.5 or contact the manufacturer for
additional instructions on proper procedures.
NOTE: The unit is shipped with approximately 30% state-of-charge (SOC). Upon
receipt the battery shall be fully charged using the procedures listed in this manual
(prior to storage and again prior to installation/use).
Upon receipt the battery shall be fully charged. Batteries that are stored thereafter shall be
fully recharged at a minimum every six (6) months, following the procedure set forth in
Section 5.4.2. For more detailed storage instructions refer to Section 5.6.