32
Manual Number 9019286 • Revision E, January 06, 2022
ARINC 429 Label Format Definition
Label
Parameter Name
Data Type Range Units
Sig
Bits
Resolution
Transmit Interval
(ms)
Min
Max
271
Battery Discrete
Outputs
DISCRETE
-
-
-
-
250
500
340
DC Current
BNR
± 4096
A
15
0.125
250
500
341
DC Voltage
BNR
64
V
15
0.001953
250
500
342
Battery Temperature
BNR
± 512
C
12
0.125
1000
2000
343
Deliverable Energy
BNR
512
Ah
13
0.0625
1000
2000
344
Capacity
BNR
512
Ah
13
0.0625
1000
2000
345
State of Charge
BNR
128
%
11
0.0625
1000
2000
346
Estimated Life
Remaining
BNR
128
%
11
0.0625
1000
2000
350
Software Version
DISCRETE
X.Y.Z
-
-
-
1000
2000
351
Operational Status
DISCRETE
-
-
-
-
500
1000
352
Fault Status
DISCRETE
-
-
-
-
500
1000
377
Equipment ID
DISCRETE
-
-
-
-
1000
2000
Table 4.4
ARINC 429 Label Format
Fault Status Indications for ARINC Label 352:
Invalid Configuration
Stack Over Voltage
Cell Over Voltage
Charge Cell Over-temp (Disable Charging)
Over Current
Short Circuit
Cell Under Voltage
Stack Under Voltage
Discharge Cell Over-temp (Disable Discharging)
FET Over-temp
Continuous BIT Fault
Continuous BIT Failure
End of Life
Over-Discharge
Heater Fault
Heater Fail
Module Charge Required