Needed components for connection to water circuit
It is advised to use hose nut with external thread PN16 50 x 6/4” and a pressure hose D50 or PVC
pipe D50.
Particular component selection depends on individual condition at your pool. Your seller,
distributor or pool builder may decide on how the actual connection is performed. These
components are not part of heat pump package or delivery.
Important:
For proper operations, there must be a water flow through the heat pump
exchanger in range of 4-6 m
3
/hour. In the
case of water flow exceeding 10m
3
/h the heat
pump will turn itself off and an error notice PL
will pop up. Repeated error notice or repeated
exposure of the heat pump to the water flow
higher than 8m
3
/h will cause irreversible
damage to flow switch with permanent error
notice PL. The heat pump will be turned off.
Please contact your distributor or service
department, the flow switch needs to be
replaced.
Picture: Pressure hose
D50
Picture: Hose nut with external thread PN16.
G=6/4” D=50mm
Picture: PVC pipe, various
dimesions