MDS 05-3301A01, Rev. C
MDS 9810 Installation and Operation Guide
35
6.4 Detailed Command Descriptions
The essential commands for most applications are Network Address
(
ADDR
), Mode, (
MODE
) and Baud Rate (
BAUD
). However, proper use of
the additional commands allows you to tailor the transceiver for a spe-
cific use, or to conduct basic diagnostics on the radio. This section gives
more detailed information for many of the user commands listed in
Table 6.
Most of the commands below can be used in two ways. First, you can
type only the command name (for example,
ADDR
) to view the currently
programmed data. Second, you can set or change the existing data by
typing the command, followed by a space, and then the desired entry
(for example,
ADDR 1234
). In the list below, allowable programming
variables, if any, are shown in brackets [ ] following the command
name.
DISPLA
Y OPERA
TING ST
A
TUS
(CONTINUED)
SNR
Details Page 46
Signal-to-noise ratio. Expressed in dB.
SREV
Details Page 47
Display transceiver firmware revision level
STAT
Details Page 47
Show current alarm status
TDD [ON/OFF]
Details Page 47
Sets or displays time-division multiplex status of
DATA INTERFACE connector. (Sometimes
referred to as “simulated full-duplex” mode.)
TEMP
Details Page 48
Transceiver’s internal temperature (°C)
UNIT [10000–65000]
Details Page 48
Show programmed unit address for net-
work-wide diagnostics
ZONE DATA
Details Page 49
Show zone data statistics (see text for details).
Press “Q” to quit.
DIA
GNOSTIC/TEST
KEY
Enables the transmitter.
(Radio must be in Setup mode.)
DKEY
Disables the transmitter.
(Radio must be in Setup mode.)
DMGAP [xx]
Details Page 39
Sets the amount of time to wait after the
receipt of a character before interpreting the
next received character as the start of a new
message.
TX [xxxx]
Details Page 48
Set/display transmit test frequency.
(Radio must be in Setup mode.)
RX [xxxx]
Details Page 43
Set/display receive test frequency.
(Radio must be in Setup mode.)
SETUP
Details Page 44
Enables Setup mode. Times out after 15 min-
utes. Press “Q” to quit.
Table 6. Command Summary (Continued)
COMMAND
DESCRIPTION