Microtronix Access User Guide
X.25
State
The current state of the gateway session towards the X.25 logical channel
Disconnected / Connecting / Listening / Reconnect / Waiting / Connected /
Flow Control
Device
The Device being used for the connection to the remote X.25 Host. May be
one of: hdlc0, hdlc1, XOT
Calling
address
The X.121 address of the initiator of the X.25 connection.
Called
address
The X.121 address of the X.25 destination.
6.4 Control and Log
This page provides status and control of X.25-TCP gateway application. System log messages
pertinent to this application will be displayed.
The current status of the application are indicated by a
Running
or
Stopped
indicator. Stopping or
restarting the application will disconnect any active sessions and the associated TCP and X.25
communication sockets will be closed. If the application is stopped, then a
Start
button will be
displayed to start it again. The system log scrolling region shows significant application events since the
box was started. If there are any unusual errors, they will be shown in the log.
51