ENGLISH - 23
save the test result.
When using
Method A, the
effects of both
launch cables and one coupler are removed.
METHOD B
This method is commonly
recommended by ISO 11801
and ANSI/EIA/TIA 568A.
For Method B, one launch
cable is used to set the
reference.
The launch cable will be
canceled out for all subse-
quent measurements.
1. Connect one end of a
Launch Cable to
SimpliFiber
Meter.
2. Connect the other end of
the same Launch Cable to
SimpliFiber
Source.
3. Power on
SimpliFiber
Source and press
. To
choose the appropriate
wavelength, 850 or 1300,
2m Launch Cable
SimpliFiber
Source
METHOD B
SimpliFiber
Meter