10          Microtek TMA1600  Installing  and  Getting  Started

C. Using the 6 x 9 cm Filmstrip Template

The 6 x 9 cm Filmstrip Template allows you to scan varying sizes of transparencies,
including 6 x 4.5 cm, 6 x 6 cm, 6 x 7 cm, and 6 x 9 cm. The maximum number of film that
can be loaded depends on the size of your film. (e.g., the 6 x 4.5 cm can hold up to 4
pieces of film, the 6 x 9 cm can hold up to 2 pieces of film)

1. Load the film face down inside the template. Slide the film along the slots of the

template until its edge is against the side of the template (indicated by an arrow
mark ).

2. Slide the black plate* until its edge is against the film, thus covering the blank

spaces. The side of the black plate (which reads “This side up”) should face up.

2

1

0

3

4

5

6

6

5

4

3

2

1

3. Place the template assembly on the scanner glass surface.

Align  the  edge
of  the  film  frame
with  the  arrow
mark  of  the
template

Содержание TMA 1600

Страница 1: ...rofile 19 Specifications 20 Copyright 2001 Microtek International Inc http www microtek com I49 003257 A December 2001 Installing and Getting Started MicrotekTMA1600 Trademarks Microtek ScanMaker and...

Страница 2: ...ument cover or scanner lid The TMA1600 can be mounted on or removed from the top of the scanner in the same way as the scanner lid Unpacking the Package The TMA1600 is packaged as an assembled unit re...

Страница 3: ...A1600 must be locked To lock the TMA1600 follow the steps below 1 Make sure the TMA1600 is connected to the scanner then turn off the scanner if your scanner is on 2 Set the scanner SCSI ID number to...

Страница 4: ...nner s power switch to Off Your scanner is compatible with the TMA1600 Your scanner has been installed and is working properly Your TMA1600 is unlocked To install the TMA1600 follow these steps 1 Remo...

Страница 5: ...s connector into the 15 pin Accessory port at the back panel of the scanner Secure the connector by tightening the retaining screws 4 Turn the scanner s power switch to On and wait for the green ligh...

Страница 6: ...aterials such as photographic or prints You do not need to remove the TMA1600 to scan reflective materials Positioning transparent originals To scan various sizes of transparent originals you will nee...

Страница 7: ...ler of the scanner and that the two edges left and right fit within the scanner glass area 5 Gently lower the TMA1600 down onto the scanner glass surface 2 1 0 3 4 5 6 6 5 4 3 2 1 2 1 0 3 4 5 6 6 5 4...

Страница 8: ...into the template next 1 Place the template which the side reads Microtek logo should face up on the scanner glass surface 2 1 0 3 4 5 6 6 5 4 3 2 1 Make sure that the template s front corners are fir...

Страница 9: ...s at a time 1 Load the film face down inside the template Slide the film along the slots of the template until its edge is against the side of the template indicated by an arrow mark 2 Place the templ...

Страница 10: ...ieces of film the 6 x 9 cm can hold up to 2 pieces of film 1 Load the film face down inside the template Slide the film along the slots of the template until its edge is against the side of the templa...

Страница 11: ...dge of the template indicated by an arrowmark 2 Place the template assembly on the scanner glass surface Center the top of the template along the top ruler on the scanner aligning the template s arrow...

Страница 12: ...hat nothing is on the scanner glass surface 2 Place the X ray original face down on the scanner glass surface Center the top of the X ray original along the top ruler on the scanner 2 1 0 3 4 5 6 5 4...

Страница 13: ...on the scanner glass surface Center the top of the template along the top ruler on the scanner 3 Peel the protective film from the black plate 4 Put the black plate on top of the reflective original...

Страница 14: ...e quality during scanning Caution 1 The black plate may become dirty over time and with prolonged use To clean the plate use a white cotton cloth dipped in some water and gently wipe the plate surface...

Страница 15: ...File menu of your image editing application then select ScanWizard Pro To operate ScanWizard Pro in the stand alone batch mode in Macintosh systems go to the Apple menu and choose the Batch Scan comm...

Страница 16: ...overview and you will see the thumbnail image appear in your Scan Job Queue window 6 If you like what you see in the Preview window click the Scan button to start scanning The image is then delivered...

Страница 17: ...ective sleeve and avoid touching the target image surface When not in use keep the target in its sleeve and away from light and heat Note To keep the colors in your scanner consistent you should perfo...

Страница 18: ...le click the ICC Profile icon In Windows select the Start menu Programs Microtek ScanWizard Pro for Windows then Microtek Scanner ICC Profiler 3 The main dialog box appears Set the appropriate paramet...

Страница 19: ...exit Scanner ICC Profiler program Loading a profile Once the profile has been produced follow the steps below to load the profile you just created 1 Launch ScanWizard Pro 2 From the Preview window cl...

Страница 20: ...colors 16 bit grayscale approx 65 536 shades of gray Scanning area Transparent 12 x16 305x406mm Reflective 12 x17 305x431 8mm Resolution Optical 1600 dpi x 3200 dpi Interpolated 12800 dpi x 12800 dpi...

Отзывы: