background image

BACK PANEL

N E L

7

1

6

2

3

4

5

1. Mains Input Terminal Block for AC input.

2.  Circuit Breaker for mains overload / short circuit protection. 

(4Amps/7Amps  for  IN-600VA  Model,  8Amps/10Amps  for 
IN-800VA Model & 10Amps/16Amps for IN-1400VA Model). 

3. Output socket for load.

4. Positive Battery Lead.

5. Negative Battery Lead.

.

7. Fuse (10Amp Slow Blow for all models) for Charger.

6 Slide Switch to Select the Maximum Charging Voltage.

(HIGH= 14.2V DC    /    Standard (STD)= 13.8 V DC).

     Select the appropriate Voltage as recommended by the Battery 

Manufacturer/Supplier. 

CAUTION:  Proper selection of switch position is recommended based on the battery manufacturers specifications, 

for proper backup and also to avoid any damage to the battery due to wrong selection.

In case of IN-600VA / IN-800VA - 12V Batt. Sys.

In case of IN-1400VA                 - 24V Batt. Sys.

6

Содержание IN-1400VA

Страница 1: ...WINNER OF SMART LIVING AND EFY AWARDS ...

Страница 2: ... of the millions of satisfied users of Microtek Products Before using this inverter Please read this manual carefully to familiarize yourself with all its features controls and safety precautions Enjoy Uninterrupted Power 1 AN ISO 9001 2000 COMPANY WINNER SMART LIVING EFY AWARDS WINNER SMART LIVING EFY AWARDS ...

Страница 3: ...2 ...

Страница 4: ... Page 05 Back Panel Page 06 Load Chart Page 07 Noise on Inverter Mode Page 07 Troubleshooting Page 08 Bypassing the Inverter Page 10 Technical Specifications Page 11 Servicing Page 12 Warranty Page 12 Safety Instructions Page 14 Important Page 14 Going on Vacations Page 14 3 ...

Страница 5: ...TURES MICRO CONTROLLER BASED DIGITAL INVERTERS are designed using latest state of the art Technology for Better Performance and High Reliability The Digital Technology used enhances the life of the battery and minimum effort has to be put for maintenance 7 MICRO CONTROLLER BASED Intelligent Control Design 7 Display Indications Status Fault 7 CCCVTechnology withAutoTrickle Mode 7 Smart Overload Sen...

Страница 6: ...Charging LED Continuously Glows when Charged LED Blinks when Battery is Charging 4 Fuse Blown 5 Inverter Overload 6 Battery Low II Switch 7 Power On Off Reset 5 7 1 2 3 5 6 4 MAINS ON INVERTER ON BATTERY CHARGING STATUS INVERTER OVERLOAD BATTERY LOW FUSE BLOWN FAULT ...

Страница 7: ...ead 7 Fuse 10Amp Slow Blow for all models for Charger 6 Slide Switch to Select the Maximum Charging Voltage HIGH 14 2V DC Standard STD 13 8 V DC Select the appropriate Voltage as recommended by the Battery Manufacturer Supplier CAUTION Proper selection of switch position is recommended based on the battery manufacturers specifications for proper backup and also to avoid any damage to the battery d...

Страница 8: ...rved from tube light fan which is due to the following reasons 1 Because of inferior quality choke 2 Weak Leaky capacitor in fan These noises may not be present while on mains mode but shall be on the inverter mode because of TPZi waveform which allows higher backup as compared to Sine Wave Mains Waveform in inverter mode with noise as nuisance This can be reduced by Loading the inverter output wi...

Страница 9: ... No output from inverter c Check Circuit Breaker at the Rear Push the Circuit Breaker Reset to Switch On the output If it trips again call electrician to check shorting overload in the load wiring 2 Inverter trips frequently at inverter mode The load is more Reduce the load and reset the inverter 3 Inverter Mode but no power a Overload a Reduce the load and turn the reset switch on the front panel...

Страница 10: ...FF OFF ON 4 Backup time less a Check battery water and charge the battery with mains minimum for 8 12 hours If still less backup get the battery checked up from authorised service personnel 5 Inverter does not operate a Check the battery connections and the mains connections b Internal problem Bypass the inverter as explained in next section and call authorised service personnel LED Low Battery Re...

Страница 11: ... taken to ensure that the INVERTER ON SWITCH has been switched off in order that the battery does not discharge To bypass the inverter follow the following steps 1 Remove input plug from the wall socket 2 Remove output plug from the inverter s output socket and 3 Insert output plug into the wall socket OR Alternatively use a two way bypass switch externally Simply make it ON to Bypass Mode By Pass...

Страница 12: ...e as Input Output waveform on inverter mode TPZi Wave form TRAPE ZOIDAL WAVEFORM Battery charging current Constant charging approx 10 of the rated battery current in AH Charger Constant current Constant wattage Efficiency 84 Inverter Overload 100 Inverter short circuit 300 Browns out mains voltage 100V 40V Technology MICRO CONTROLLER BASED DESIGN Auto Reset Feature Yes NOTE Because of a policy of ...

Страница 13: ...ompany or authorised Service center under a written intimation and which to the company s satisfaction be found defective The company reserves the right to decide as to whether the repair work should be carried out in the company s service center or at site or at any other place The freight incurred for to and fro dispatch will have to be borne by the customer and the transit risk for the material...

Страница 14: ...uthorised Distributors dealers or any third party Until superceded otherwise or in contractual form this warranty is made expressly in lieu of all other liabilities and obligations on part of MICROTEK International P Ltd Title to the Instrument passes to the buyer upon delivery to the common carrier POST WARRANTYANNUALMAINTENANCE CONTRACT For Microtek Inverters Microtek Offers Annual Maintenance C...

Страница 15: ... accessible for servicing Foreign objects and water must not enter the inverter Always ensure that objects containing liquid are avoided near the unit In the event of any instrument requiring service at our authorised service centre the following procedure should be adopted 1 The instrument must be securely packed preferably in its original packing 2 The instrument should be despatched on Freight ...

Страница 16: ...address e mail ID if any iii Reported problem description of complaint Note a Refer all servicing queries to Microtek Authorised Dealer or Microtek Service Centres only b Please take care that Serial Number is kept intact and that the product is not allowed to be fiddled opened by any unauthorised person otherwise the warranty will be void Service H O Tel 011 42733333 E mail power support microtek...

Страница 17: ...H 57 Udyog Nagar Rohtak Road New Delhi 110041 Sales Tel 011 42733377 Sales E mail sales microtekdirect com Service E mail power support microtekdirect com ...

Отзывы: