background image

Getting to Know Your Bio-5000

The Bio-5000 is a combined flatbed and film scanner for electrophoresis gels and film
formats that also offers additional functionality to scan reflective art or prints as large
as 8.5" x 14". The Bio-5000 is equipped with Microtek's patented Emulsion Direct
Imaging Technology (E.D.I.T.) for delivering distortion-free images in transparency
scanning. The 0.05 minimum optical density (Dmin) provides a wider and clearer range
for capturing light tones of images.

Copyright © 2013  Microtek International, Inc.   http://www.microtek.com
I49-004655 E, September 2013

Bio-50

0

0

 f

e

a

tures, scenarios, and inf

ormation

Supplement

Contents

Getting to Know Your Bio-5000 ....................................................................... 1
Features of the Bio-5000 .................................................................................. 2
Taking a Closer Look ........................................................................................ 3

Unlocking the Scanner .................................................................................... 4
Positioning Your  Originals .............................................................................. 5

Positioning Electrophoresis Gels ........................................................... 6

Using the Leak-Free Glass Holder .................................................. 6

Positioning Transparent Film ................................................................. 7

Using the Leak-Free Glass Holder .................................................. 7

Positioning Reflective Originals ............................................................. 8

Scanning Scenarios ......................................................................................... 9

Scanning Electrophoresis Gels ............................................................ 10
Scanning Transparent  Film ................................................................... 12
Scanning Reflective Originals ............................................................... 14
Scanning Originals Applied with Auto Focus ..................................... 16

Specifications / System Requirements ........................................................ 18
FCC Compliance Statement .......................................................................... 19

Содержание Bio-5000

Страница 1: ...opyright 2013 Microtek International Inc http www microtek com I49 004655 E September 2013 Bio 5000 features scenarios and information Supplement Contents Getting to KnowYour Bio 5000 1 Features of th...

Страница 2: ...ds Auto Focus allows the scanner to change the focus position on images through the movement of the CCD resulting in better image quality for a chosen area of the scan Auto Focus is activated by defau...

Страница 3: ...g a Closer Look Horizontal ruler Scanner lid Glass surface Upper scan bed Vertical ruler Power button Power indicator green Reflective Ready indicator amber Transparency Ready indicator amber Power co...

Страница 4: ...a little protruding slightly from the bottom of the scanner Shipping the Scanner If you have to transport the scanner you will need to lock the scanner back Follow the steps below 1 Turn off the scann...

Страница 5: ...en t film sc an nin g The correct side up is the side showing the holder labels facing up When using the Leak Free Glass Holders make sure you use the correct side up when inserting the holders into t...

Страница 6: ...K F R E E G L A S S H O L D E R T hi s ho l d er i s sp ec i f i c al l y de si gn ed fo r th e us e of th e ge l an d tr an sp ar en t fil m sc an ni ng Keep calibration strip clear and free of any o...

Страница 7: ...s ho l d er i s sp ec i f i c al l y de si gn ed fo r th e us e of th e ge l an d tra ns pa re nt fil m sc an ni ng Keep calibration strip clear and free of any obstruction 3 Insert the holder all th...

Страница 8: ...1 Open the scanner lid 2 Place the original to be scanned face down on the scanner glass bed towards the front of the scanner Center the top of the original along the horizontal ruler on the scanner...

Страница 9: ...ng transparent film This scenario details the steps for scanning transparent film such as 4 x 5 positive or negative film Scanning reflective originals This scenario details the steps for scanning ref...

Страница 10: ...as well in the Scan Job Queue window 7 Specify your scanning requirements in the Settings window a Select a desired image type b Select a desired resolution c Adjust the scan frame settings if necess...

Страница 11: ...Bio 5000 Supplement 11...

Страница 12: ...ame marquee around the selected area 6 Click the Prescan button to display a detailed image A thumbnail of the image appears as well in the Scan Job Queue window 7 Specify your scanning requirements i...

Страница 13: ...Bio 5000 Supplement 13...

Страница 14: ...ted via the Scan Frame tool A thumbnail of the image appears as well in the Scan Job Queue window 7 Specify your scanning requirements in the Settings window a Select a desired image type b Select a d...

Страница 15: ...Bio 5000 Supplement 15...

Страница 16: ...e image If this is the first time to scan your scan material you can see a flashing frame enclosed by dotted lines together with a default Auto Focus target sign appearing on the preview area The Auto...

Страница 17: ...n the scan frame labeled with the tag AF Note The AF frame works only in the area defined by the scan frame 4 In the Preview window click the Prescan button This will give you a more detailed view of...

Страница 18: ...t grayscale approx 65 536 shades of gray Scanning Area Reflective Max 8 5 x14 216mmx356mm Min 0 75 x0 75 19mmx19mm Transparency Max 8 x10 203mmx254mm Min 0 75 x0 75 19mmx19mm Resolution Optical 4800 d...

Страница 19: ...d on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and rec...

Страница 20: ...20 Bio 5000 Supplement...

Отзывы: