6.2.
Connecting of the Analog Output
●
Analog output is one such type is configured in the Order Code
6.3.
Connecting of the Digital Input
6.4.
Connecting of the Digital Outputs
Discrete outputs are identical and are of two
types - relays or isolated open collector.
Relay outputs have a common contacts and
transistor outputs are with common emitters.
6.5.
Connecting of the RS485
Signals A and B are connected to the corresponding line of RS485.
If the device is the last in the line include a termination resistor by Jumper- R term.,
next
to the
terminals of the RS485
VII. OPERATING MODES
The controller is used as a part of controlling of processes for dosing of materials. Based on
measured input weight three digital and one analog output are formed. Supports 4 sets of operating
set points:
•
Dose 1 / weight of changing of K1 “dose 1”
•
Dose 2 / weight of changing of K2 “dose 2”
•
Dose 3 / weight of changing of K3 “dose 3”
Selection of one of the four sets when setting the set-points or in operating mode is set by
combination of the inputs S1, S2. The controller indicates which set of parameters is chosen for
current in the heading of “Prog” menu - Prog 1, 2 etc.
Document revision 2015-08-17