migra MPB PB
Large Format, Graphics Compatible Display with Profibus Interface
Page 43
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach
+49 9681 91960-0,
+49 9681 91960-10, [email protected], www.microsyst.de
25-Pin Sub-Miniature Plug Connector (only with optional parallel inputs)
Binary data:
Data with a value ranging from 0 to 255 as the number
of a text, a graphic or a macro, or as the ASCII character
of a variable to be displayed.
Display / clear:
Displays or clears the selected object.
Query text:
Displays or clears the selected text.
Query graphic:
Displays or clears the selected graphic.
Query variable:
Displays the ASCII character defined by means of
binary data at the position of the selected variable.
Query macro:
Starts / stops macro execution at the selected macro.
Strobe:
If high level is applied to pin 16 (> 110 ms), the selected
data are transferred (command is executed no later than
100 ms after the rising edge, except when the display unit has
not yet completed processing of any other command).
Please r
efer to chapter “Parallel Interface” for details concerning the parallel
inputs.
Pin 1
Binary data 2
0
Pin 2
Binary data 2
1
Pin 3
Binary data 2
2
Pin 4
Binary data 2
3
Pin 5
Binary data 2
4
Pin 6
Binary data 2
5
Pin 7
Binary data 2
6
Pin 8
Binary data 2
7
Pin 9
Variable no. 2
0
Pin 10
Variable no. 2
1
Pin 11
Variable no. 2
2
Pin 12
Variable no. 2
3
Pin 13
Display / clear (1: display, 0: clear)
Variable no. 2
4
Pin 14
Function selection 2
0
Pin 15
Function selection 2
1
Pin 16
Strobe (1: apply value now)
Pin 17-24
n.c.
Pin 25