migra MPB PB
Large Format, Graphics Compatible Display with Profibus Interface
Page 24
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach
+49 9681 91960-0,
+49 9681 91960-10, [email protected], www.microsyst.de
3.6.4 General Functions
3.6.4.1 Set Blinking Period Duration
Byte 1
Byte 2
Byte 3
ESC
Function
Period duration
1B
h
“B”
“0”: 2 seconds
:
“9”: 0.2 seconds
The selected blinking period duration is assigned to all blinking texts.
The default
value is “9” (0.2 seconds) is activated each time the device
is switched on.
3.6.4.2 Adjust Brightness
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
ESC
Function
Colour
Brightness
hundreds
Brightness
tens
Brightness
ones
1B
h
“H”
“1”: green
“2”: red
“0” – “1”
“0” – “9”
“0” – “9”
Each within a range of 0 to 100%:
“1” = green
“2” = red.