3.8  Multiple ESC-Sequences 

 

It is possible to combine several partition frames in one complete frame. 
This applies to the standard controlling and to the macro list. 
 
The partition frames can be a ESC-sequence or a online text each. 
 
If a online text shall follow after the ESC-sequence, it must be separated 
with the “separator sign“ 1F

H

 from the ESC-sequence. The separator it-

self is not evaluated. 
 
The maximum length of the data unit of a complete frame is 230 charac-
ters (maximum 193 characters with Profibus). 
 
 
Example: 
 
Data unit = 1B

H

 

“Z01“ 1B

H

 

“C002003“ 1B

H

 

“A301“ 1F

H

 

“online text“ 

 
=> An “online text” with character set 1, at cursor position x=2, y=3 with 
foreground colour “yellow“ and background colour “black“ is displayed 
(blinking). 
 

 

 

Содержание migra MPB PB

Страница 1: ...lectronic GmbH Am Gewerbepark 11 92670 Windischeschenbach 49 9681 91960 0 49 9681 91960 10 info microsyst de www microsyst de migra MPB PB Large Format Graphics Compatible Display with Profibus Interf...

Страница 2: ...Position the Cursor 14 3 6 1 3 Configure Attributes 14 3 6 2 Texts Graphics Variables and Bargraphs 15 3 6 2 1 Query Text 15 3 6 2 2 Adjust Speed for Moving Screen Texts 15 3 6 2 3 Query Graphics 15 3...

Страница 3: ...1 30 3 9 4 Set Variable No 1 to 3000 30 3 9 5 Increase Variable No 1 30 3 10 Parallel Interface 31 3 10 1 Timing at the Parallels Inputs 31 3 10 2 Input Levels at the parallel Inputs 31 3 10 3 Query T...

Страница 4: ...olour model MC Display Functions Data transmission Profibus DP serial interface RS232 or parallel interface optional Configuration with PC software via serial port Visualisation Texts different font s...

Страница 5: ...voltage 230 V 50 Hz 110 V 60 Hz or 24 VDC 20 Interface Profibus DP serial parallel optional Housing powder coated aluminum Housing dimensions see chapter device configuration Mounting articulated arm...

Страница 6: ...cable to the power supply When disconnecting the power supply the following sequence has to be observed o Disconnect the power supply cable from the power supply o Disconnect the power supply cable f...

Страница 7: ...green yellow white blue View single sided double sided Operating voltage 230 V 50 Hz 110 V 60 Hz 24 V DC Protection IP40 IP54 IP65 IP _____ Operating temperature with type for inside use with type for...

Страница 8: ...t de 3 3 Display Elements Alphanumeric display modules with 16 x 16 64 x 8 or 64 x 16 dot matri ces are utilized Attention As far as the software is concerned there is no difference be tween modules w...

Страница 9: ...he device is in boot mode This indicates that the software currently stored on the integrated flash memory is in complete This may have been caused by a previously interrupted up load operation If thi...

Страница 10: ...n received depending up on baud rate settings The pause between the individual frame bytes may not exceed this period of time The pause between the individual frames must exceed this period of time Th...

Страница 11: ...010B 1XXXXXXXB 1XXXXXXXB 1XXXXXXXB STX Start of text 02H DA RS232 485 address of the internal controller 81H 82H 83H 80H device address This is no Profibus address SA Source address 80H This is no Pro...

Страница 12: ...he display unit All variables graphics and texts are written to the display starting at the selected x and y coordinates and then proceeding down and to the right The display s physical limits may not...

Страница 13: ...ursor position ESC C If the display limits are exceeded display output is continued at the next line or at the first line of the display unit 3 6 1 1 Select Character Set Byte 1 Byte 2 Byte 3 Byte 4 E...

Страница 14: ...ion the Cursor Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 ESC Function x Position hundreds x Position tens x Position ones y Position hundreds y Position tens y Position ones 1Bh C 0 9 0...

Страница 15: ...colour from the last ESC A frame Black is used if the background colour has been set to transparent 3 6 2 2 Adjust Speed for Moving Screen Texts Byte 1 Byte 2 Byte 3 ESC Function Moving Speed 1Bh L 0...

Страница 16: ...e 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 133 ESC Function Set Var no hundreds Var no tens Var no ones Variable values 1Bh V set 0 9 0 9 0 9 20h FFh Variables may include up to 127 characters the length...

Страница 17: ...outputted The background colour used with the variables may not be transparent and a character set with uniform character width should be used in order to assure correct display Otherwise the variable...

Страница 18: ...learing a bargraph means to fill the bargraph area with the current online background colour from the last ESC A frame Black is used if the online background colour has been set to transparent If a va...

Страница 19: ...position of the reference value If the bar exceeds one of the colour borders starting at the reference value it will be shown in the new defined colour after this point Four colour borders are defined...

Страница 20: ...e starting at the right If a variable is preset to preceding zeros are suppressed replaced with blanks If a variable is preset to preceding zeros are displayed If a digit is occupied by the dollar sig...

Страница 21: ...Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9 ESC Function Colour x pos hundreds x pos tens x pos ones y pos hundreds y pos tens y pos ones 1Bh P 0 black 1 green 2 red 3 yellow 0 9 0 9 0 9 0 9 0 9...

Страница 22: ...d 3 yellow 0 black 1 green 2 red 3 yellow T transparent Upper left Corner Position Byte 5 Byte 6 Byte 7 Byte 8 Byte 9 Byte 10 x position hundreds x position tens x position ones y position hundreds y...

Страница 23: ...ically in steps of 1 to 9 pixels The start and end line defines the Y position of the first and last pixel line of the scrolling range end line start line Only the last selected scrolling range is use...

Страница 24: ...Period Duration Byte 1 Byte 2 Byte 3 ESC Function Period duration 1Bh B 0 2 seconds 9 0 2 seconds The selected blinking period duration is assigned to all blinking texts The default value is 9 0 2 se...

Страница 25: ...digital inputs and 16 digital outputs Request Frame Byte 1 Byte 2 Byte 3 Byte 2 n Byte 18 ESC Function Output bit 1 Output bit n Output Bit 16 1Bh D 0 or 1 0 or 1 0 or 1 0 clear output 1 set output e...

Страница 26: ...Execution Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 ESC Function Macro no hundreds Macro no tens Macro no ones 1Bh M 0 9 0 9 0 9 Execution starts with the indicated macro Skipping is also possible during ma...

Страница 27: ...ation address Source address Frame control Error code End of text 02H 80H 81H 82H 83H 80H 0 5 30H 35H 03H Error Codes and their Meanings Value ASCII character Meaning 0 No error 1 Reserved 2 Reserved...

Страница 28: ...and to the macro list The partition frames can be a ESC sequence or a online text each If a online text shall follow after the ESC sequence it must be separated with the separator sign 1FH from the E...

Страница 29: ...me the Migra notifies its anew readiness with the response frame 02 80 81 80 30 03 _________ Header Trail Error Code 3 9 1 Write Online Text Hello World STX DA SA FC Start of Text Display Address Sour...

Страница 30: ...81H 80H 81H Data Unit Querying Variables ETX ESC V 0 0 1 End of Text 1BH 56H 2BH 30H 30H 31H 03H 3 9 4 Set Variable No 1 to 3000 STX DA SA FC Start of Text Display Address Source Address Frame Control...

Страница 31: ...crosyst de www microsyst de 3 10 Parallel Interface Functions can be initialised via the 16 digital inputs which are analogous to the online frames used for the serial interface 3 10 1 Timing at the P...

Страница 32: ...49 9681 91960 0 49 9681 91960 10 info microsyst de www microsyst de 3 10 3 Query Text 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 For example the following assignments are used to display text 12 16 15 14...

Страница 33: ...9681 91960 0 49 9681 91960 10 info microsyst de www microsyst de 3 10 4 Query Graphics 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 For example the following assignments are used to clear graphic 7 16 15 14...

Страница 34: ...10 9 8 7 6 5 4 3 2 1 Example The variable at the fourth digit is to be changed at a display with 6 variables Each digit is implemented by means of a variable numbers 0 through 5 In order to display a...

Страница 35: ...T Systemelectronic GmbH Am Gewerbepark 11 92670 Windischeschenbach 49 9681 91960 0 49 9681 91960 10 info microsyst de www microsyst de 3 10 6 Querying Macros 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Num...

Страница 36: ...fibus DP Interface ID Number 05D0h GSD File MICR05D0 GSD Cyclical User Data max 200 bytes output max 200 bytes input max 300 bytes output input Standard Configuration 2x 0x3F 32 input output bytes Par...

Страница 37: ...ifying these identifiers in any order the desired total data width is set for both the input and the output data Data Identifier Number of Bytes Function Description 0x10 1 Input data 0x11 2 Input dat...

Страница 38: ...t support any extended diagnosis data Default di agnosis is utilised 3 11 3 DP Parameter Data The User_Prm_Data are not utilised by the interface However a test is run to determine whether or not User...

Страница 39: ...ough time for executing the current command For this it is strongly recommended to wait for the MIGRA response frame see chapter DP Input Data Alternatively a minimum waiting time has to be ensured It...

Страница 40: ...0 30 30 30 30 30 1B 5A 30 30 1B 41 33 30 30 1F 41 42 43 03 00 _________ ______ _____________________ _________ ____________ ______ Header ESC F0 ESC C000000 ESC Z00 ESC A300 Sepa Text Trail Request Fi...

Страница 41: ...0 info microsyst de www microsyst de 4 Connector Pin Assignments 9 Pin Sub Miniature Plug Connector download interface RS232 9 Pin Sub Miniature Plug Connector download interface RS485 optional If an...

Страница 42: ...es download or Profibus DP 7 Pole Mains Plug 230 VAC 3 Pin Circular Plug only with 24 VDC supply power 5 Pin Circular Plug only with optional digital outputs Relay 1 2 is con trolled by digital output...

Страница 43: ...means of binary data at the position of the selected variable Query macro Starts stops macro execution at the selected macro Strobe If high level is applied to pin 16 110 ms the selected data are tran...

Страница 44: ...lt settings Baud rate 19200 baud Data bits 8 Parity even Stop bits 1 For setting the serial interfaces the PC software MKS is mandatory LED Function Description LED 1 green Power up Blinks at a freque...

Страница 45: ...FF ON 1 Profibus address 20 0 1 D 2 Profibus address 21 0 2 D 3 Profibus address 22 0 4 D 4 Profibus address 23 0 8 D 5 Profibus address 24 0 16 D 6 Profibus address 25 0 32 D 7 Profibus address 26 0...

Страница 46: ...itch Function OFF ON 1 Internal do not change X 2 X 3 X 4 X 5 X 6 X S3 DIP Switch Function OFF ON 1 Internal do not change X 2 X 3 X 4 X 5 X 6 X 7 X 8 X LEDs LED Status Meaning red FAULT ON no Profibu...

Страница 47: ...7 xxxx1000 8 xxxx1001 9 xxxx1010 A xxxx1011 B xxxx1100 C xxxx1101 D xxxx1110 E xxxx1111 F bin hex 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 1101 1110 1111 X 0 P p X 1 A Q a q X 2 B...

Страница 48: ...bright light sources and or direct sunlight The display must be switched off before cleaning Protect the display from excessive humidity extreme vibration di rect sunlight and extreme temperatures Non...

Страница 49: ...hat the above men tioned product meets the requirements of the following standard Die bereinstimmung des bezeichneten Produk tes mit den Vorschriften der angewandten Richt linie n wird nachgewiesen du...

Страница 50: ...e of notifica tion requirements is equated with acceptance of the defect Defects and their symptoms must be described as accurately as possi ble in order to allow for reproducibility and elimination T...

Страница 51: ...13 Bargraph new DP Interface Example Onlinetext Kreuzer Layout Kreuzer Housing dimensions changed Kreuzer Receiving timeout changed Kreuzer New dummy added Kreuzer Some examples added Landgraf Pin ass...

Отзывы: