![MicroSys Electronics miriac SBC-LS1046A-TSN Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/microsys-electronics/miriac-sbc-ls1046a-tsn/miriac-sbc-ls1046a-tsn_user-manual_1789236010.webp)
Quick Start Guide 3
miriac SBC-LS1046A-TSN_User Manual
V 2.0
10/68
© MicroSys Electronics GmbH 20178
3
Quick Start Guide
3.1
Prerequisites
Always make sure to handle the SBC-LS1046A-TSN unit ESD-
safe! Otherwise, the unit may suffer permanent damage.
However, do not place the unit directly flat on a metal surface,
as this may result in short circuits and damage to the board.
At first time operation unpack the unit and make sure that is clean and free of visible
damage or foreign objects.
3.1.1 Minimum Requirements
To operate the board, you will at least need the following items:
■
an adequate power supply, delivering 12V DC (stabilized) / 2A minimum.
■
an USB cable (type A
– mini B) adapted to connector ST5
■
a serial terminal, such as a PC with an USB port running a terminal Software
(e.g. TeraTerm, HyperTerminal, putty, ckermit...), or else a hardware serial
console.
Choose the following parameters:
(a)
115200 Bd
(b)
8 Data bits
(c)
No parity
(d)
1 Stop Bit
3.1.2 Recommended Items
The following items are not absolutely necessary, but strongly recommended for
practical operation and development purposes:
■
Network connection to your local network installation
■
TFTP server available for downloading within the network (Hint: may run on the
same PC as the serial Terminal)
■
SD card as mass storage and/or boot media