Quick Start Guide 3
miriac SBC-LS1043A2 User Manual
V 2.2
13/72
© MicroSys Electronics GmbH 2017
3.3
Operation
After Power-up, the green LED on the module should light up
and any red LED should be off.
IF NOT, DISCONNECT THE UNIT FROM POWER AND CHECK
FOR FAULTS!
3.3.1 U-Boot Startup
When power is supplied the system will start.
On startup, U-Boot will come up similar to the following:
The exact output may vary, depending on U-Boot and MPX-LS1043A2 module
versions in use.
U-Boot 2016.09 (May 08 2017 - 14:45:17 +0200)
SoC: unknown (0x87920610)
Clock Configuration:
CPU0(A53):1600 MHz CPU1(A53):1600 MHz CPU2(A53):1600
MHz
CPU3(A53):1600 MHz
Bus: 400 MHz DDR: 1600 MT/s FMAN: 500
MHz
Reset Configuration Word (RCW):
00000000: 08100010 0a000000 00000000 00000000
00000010: 33580002 00000002 60044000 c1002000
00000020: 00000000 00000000 00000000 01036ffc
00000030: 20004504 00001200 00000096 00000001
Model: MPXLS1043 Board
Board: MPXLS1043-A2, boot from SD
I2C: ready
DRAM: Detected UDIMM Fixed DDR on board
2 GiB (DDR4, 32-bit, CL=11, ECC on)
Waking secondary cores to start from ffd0b000
All (4) cores are up.
Using SERDES1 Protocol: 13144 (0x3358)
NAND: 512 MiB
MMC: FSL_SDHC: 0
In: serial
Out: serial
Err: serial
SEC0: RNG instantiated
SATA link 0 timeout.
AHCI 0001.0301 32 slots 1 ports 6 Gbps 0x1 impl SATA mode