![Microsens MS453526M Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/microsens/ms453526m/ms453526m_hardware-manual_1788531011.webp)
Gigabit Ethernet Switch – Hardware Manual
Page 11 of 36
_______________________________________________________________
©2016_MICROSENS GmbH & Co. KG_Küferstr. 16_59067 Hamm/Germany_www.microsens.com
INSTALLING THE SWITCH
SELECTING A SITE
The switch can be mounted in a standard 19-inch equipment
rack (Via Optional Rack mount Kit) or on a flat surface. Be
sure to follow the guidelines below when choosing a location.
◆
The site should:
Be at the center of all the devices you want to link and
near a power outlet.
Be able to maintain its temperature within 0 to 45°C
and its humidity within 10% to 90%, non-condensing.
Be accessible for installing, cabling and maintaining
the devices.
Allow the status LEDs to be clearly visible.
◆
Make sure the twisted-pair Ethernet cable is always routed
away from power lines, radios, transmitters or any other
electrical interference.
◆
Make sure that the switch MS453526M is connected to a
separate grounded power outlet that provides 100 to 240
VAC, 50 to 60 Hz.
ETHERNET CABLING
To ensure proper operation when installing the switch into a
network, make sure that the current cables are suitable for
100BASE-TX or 1000BASE-T operation. Check the following
criteria against the current installation of your network:
◆
Cable type: Unshielded twisted pair (UTP) or shielded
twisted pair (STP) cable with RJ-45 connectors; Category 5
or Category 5e with maximum length of 100 meters is
recommend 100BASE-TX, and Category 5e or 6 with
maximum length of 100 meters is recommend for
1000BASE-T.
◆
Protection from radio frequency interference emissions.
◆
Electrical surge suppression.
◆
Separation of electrical wires and data based network wiring.
◆
Safe connections with no damaged cables, connectors or
shields.