3.2.2 ZL70550 Setup Display Tab
The
ZL70550 Setup
tab (refer to
) contains link setup information for the transceiver.
During operation, the
System Status and Control
section typically reflects these settings
(refer to
"3.2.1 System Status and Control"
). However, when certain test or
control functions (for example, TX carrier test) temporarily override these settings, the
overrides are reflected in the
System Status and Control
section.
Figure 5 – ZL70550 Setup Display Tab
The
ZL70550 Setup
tab contains one section,
Radio Setup
, which in turn contains one
subsection,
Frequency Setup
.
Frequency Setup
has the following fields:
−
Operating Frequency (MHz)
: This field allows the user to define the operating
frequency, in megahertz, for which the chip can be programmed. Once the
frequency is entered and the
Apply
button is pressed, the corresponding A, M,
and VCO band values are calculated for the operating frequency. If the operating
frequency is changed, a complete trim procedure is done on the transceiver.