Chapter 3
3-6
MS-810 Industrial Scanner User’s Manual
3–Ser
ial
Conf
ig.
Protocol Commands
If selecting one of the options from 0 to 4 (Point-to-Point, Point-to-Point with RTS/CTS,
Point-to-Point with XON/XOFF, Point-to-Point with RTS/CTS and XON/XOFF, or Polling
Mode D), use this format:
Format:
<
Kf
protocol>
1
Example: To change the Protocol to Polling Mode D, send
<Kf4>.
If selecting Multidrop (5), you must define an address and append it to the command
string.
Format: <
Kf5
protocol,address>
Example: To change the Protocol to Multidrop with an address of 33, send
<Kf5,33>
.
If selecting User Defined (6) or User Defined Multidrop (7), complete the format by
either choosing new parameters or concatenating unchanged data fields (separate by
commas).
TIP
: For User Defined, first select Point-to-Point
<Kf0>
and then User Defined
<Kf6...>
. For user Defined Multidrop, first select Multidrop
<Kf5>
, then User Defined
Multidrop
<Kf7...>
.
Format: <
Kf
protocol,RES,address,REQ,EOT,STX,ETX,ACK,NAK,from host>
protocol:
0 = Point-to-Point
1 = Point-to-Point with RTS/CTS
2 = Point-to-Point with XON/XOFF
3 = Point-to-Point with RTS/CTS
and XON/XOFF
4 = Polling Mode D
5 = Multidrop (requires address)
6 = User Defined
7 = User Defined Multidrop
1. Polling Mode D, Multidrop, User Defined, and User Defined Multidrop are for use with Micros-
can’s IB-105.
protocol:
5 = Multidrop
address:
Any number from 1 to 50
protocol:
6 = User Defined;
From Host:
0 = disabled
1 = enabled
Содержание MS-810
Страница 1: ...MS 810 Industrial Scanner User s Manual P N 83 000810 Rev B...
Страница 22: ...Chapter 1 1 12 MS 810 Industrial Scanner User s Manual 1 Quick Start...
Страница 82: ...Chapter 3 3 20 MS 810 Industrial Scanner User s Manual 3 Serial Config...
Страница 98: ...Chapter 4 4 16 MS 810 Industrial Scanner User s Manual 4 Utilities...
Страница 138: ...Chapter A A 40 MS 810 Industrial Scanner User s Manual Appendices...
Страница 144: ...I 6 MS 810 Industrial Scanner User s Manual Index Index...