![Microscan MS-610 Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/microscan/ms-610/ms-610_user-manual_1788361078.webp)
Appendices
A-4
MS-610 Scanner User’s Manual
A
p
p
e
ndice
s
FIS Options
MS-610 models are identified by FIS (final instruction sheet)
numbers. FIS options that are created for specific
customer applications are not listed below.
FIS #
Spot
Type
Scan
Beam
Range
Interface
R
oun
d
Ov
al
Si
ngl
e L
ine
Ra
st
er
St
an
dar
d
UH
D
RS
-2
32
R
S-4
22/
485
Visible
FIS-0610-0001
√
√
√
√
FIS-0610-0002
√
√
√
√
FIS-0610-0003
√
√
√
√
FIS-0610-0004
√
√
√
√
FIS-0610-0009
√
√
√
√
FIS-0610-0010
√
√
√
√
FIS-0610-0011
√
√
√
√
FIS-0610-0012
√
√
√
√
FIS-0610-0017
√
√
√
√
FIS-0610-0018
√
√
√
√
FIS-0610-0019
√
√
√
√
FIS-0610-0020
√
√
√
√
FIS-0610-0025
√
√
√
√
FIS-0610-0026
√
√
√
√
FIS-0610-0027
√
√
√
√
FIS-0610-0028
√
√
√
√
Infrared
FIS-0615-0005
√
√
√
√
FIS-0615-0006
√
√
√
√
FIS-0615-0007
√
√
√
√
FIS-0615-0008
√
√
√
√
FIS-0615-0013
√
√
√
√
FIS-0615-0014
√
√
√
√
FIS-0615-0015
√
√
√
√
FIS-0615-0016
√
√
√
√
FIS-0615-0021
√
√
√
√
FIS-0615-0022
√
√
√
√
FIS-0615-0023
√
√
√
√
FIS-0615-0024
√
√
√
√
FIS-0615-0029
√
√
√
√
FIS-0615-0030
√
√
√
√
FIS-0615-0031
√
√
√
√
FIS-0615-0032
√
√
√
√
Electrical Characteristics
Power Supply Requirements:
+12 VDC regulated @ 80 mA with 20 mV p-p max. ripple
–12 VDC regulated @ 80 mA with 20 mV p-p max. ripple
+5 VDC regulated @ 400 mA with 200 mV p-p max. ripple
Status Lights
Table A-4 Status Lights
LED
Lumi-
nance
Status
Power
LED
Green
On power-on
Status
LED
Red
Normal operations: illuminates when-
ever a bar code label is decoded and
remains on until a new trigger occurs.
Continuous Read or Continuous Read 1
Output: flashes for each good read.