RS-422
Format:
<
Kb
RS-422>
Example:
To enable RS-422, enter
<Kb1>
.
Note:
Whenever RS-422 is disabled, RS-232 is enabled in the background.
However, an exception occurs whenever Multidrop has been selected. In this
case the functioning protocol will be RS-485 regardless of the displayed status
of RS-422 in the menus.
Operations Commands
Triggering Mode
Format:
<
Kg
triggering mode>
Example:
To select External Edge, enter
<Kg3>
.
End of Read Cycle
Format:
<
Kh
end of read cycle mode,timeout>
Example:
To select Timeout and change the timeout value to 6 seconds,
enter
<Kh0,600>
.
Serial Trigger Character
1
Format:
<
Ki
serial trigger character>
RS-422:
0 = Disabled
1 = Enabled
triggering mode:
0 = Continuous Read
3 = External Edge
1 = Continuous Read 1 Output
4 = Serial Data
2 = External Level
5 = Serial Data & Edge
end of read cycle mode:
0 = Timeout
1 = New Trigger
2 = Timeout & New Trigger
timeout (in 10 millisecond increments):
Any number between 0 and 65535. Default is
100
(one second).
1. Avoid selecting a serial trigger character that is also an operational command. For example, an upper-
case C cannot be used as a serial trigger character because it is the operational command for Enter
Read Rate Test. However, a lowercase c could be used without initiating the read rate test.
serial trigger character:
Any available ASCII character (see “ASCII Table with Control
Characters” on page A-5). Default is
^]
.