Code Types Menu
MS-610 Scanner User’s Manual
2-21
2–Menu C
on
fig.
Check Digit Output
Default:
Disabled
Options: Disabled,
Enabled
When enabled, the check digit character is sent along with the label data.
When disabled, label data is sent without the check digit.
Large Intercharacter Gap
Default:
Disabled
Options:
Disabled, Enabled
Allows the scanner to read labels with gaps between bar code characters
exceeding three times the narrow element width.
Fixed Code Length
Default:
Disabled
Options: Disabled, Enabled
Used to increase data integrity by ensuring that only one label length will be
accepted.
Code Length
Default:
10
Options: 1 to 31
NOTE: Fixed Code Length (page 2-21) must be enabled for Code Length to
take effect.
Allows you to specify the exact number of characters that the scanner will
recognize (this does not include start and stop). The scanner will ignore any
code not having the specified length.