Microsafe Mkomfy is a safety product from CTM Lyng AS. 
The product assumes normal care in the use of the cooker 
and suitable cooking implements. A cooker should never be 
left unattended during use, even if safety equipment such as 
Mkomfy is installed. 

Timer function

When the cooker is in use, Mkomfy will detect heat on the hob and 
an integral timer will start up. After 2 hours of use the power supply 
will be cut off. This is to prevent any overheating and risk of fire if the 
cooker is forgotten or left with the elements turned on. During the final 
5 minutes of the 2-hour period (or 12 hours, see page 3), Mkomfy will 
emit a sound signal every 5 seconds. If it is wished to use the hob for 
more than 2 hours, pressing the function button will extend the user 
time by an extra 30 minutes. This may be repeated when a further sound 
signal is heard. 

Anti-tamper function

If the sensor is removed from its bracket, a safety function is activated 
and cuts off the power to the cooker. On activation, the sensor will beep 
once a second for 5 seconds, before disconnecting the cooker. 
To start the cooker, replace the sensor in the bracket and press the 
function button (short press).

Over-heating

If the cooker hob is in danger of over-heating, Mkomfy will emit a triple 
sound signal every 5 seconds. If the function button is operated by 
pressing it within 40 seconds of the first alarm, the sound signal will be 
turned off for 5 minutes in order to give you time to reduce the cooker 
temperature. If the sound signal is not turned off, power supply will cut 
out 40 seconds after the first sound signal. To re-activate the power 
supply after cut-out, press the function button.

User information

Do visit us on

www.ctmlyng.no/komfyrvakt 

or scan the QR code on the right with your 

smart phone for more information and 

documentation regarding the cooker guard. 

Содержание Mkomfy 2G R-T 25A

Страница 1: ...ructions User instructions SAVE THESE INSTRUCTIONS Fulfilstherequirements ofNEK400 2014 Mkomfy 2G R T 25A Panel installed cooker guard relay Mkomfy set with sensor and relay is supplied ready paired a...

Страница 2: ...her sound signal is heard Anti tamper function If the sensor is removed from its bracket a safety function is activated and cuts off the power to the cooker On activation the sensor will beep once a s...

Страница 3: ...cold cooker elements Battery change Battery change is normally only necessary after approx 6 years use The sensorwillwarn about battery change when necessary This will be done by 2 short sound signals...

Страница 4: ...e it is very important that the wall is carefully cleaned prior to mounting and that the wall is completely free from moisture after cleaning NB The sensor must be positioned horizontally and in the c...

Страница 5: ...ng Mounting height Height 1 Standard 50 70 cm Height 2 71 90 cm Height 3 91 105 cm Height 4 106 120 cm Mounting distances The straight line distance from the sensor eye to the centre of the hob must n...

Страница 6: ...centre of the cooker s width dimension and mark off where the bracket is to go 2 Pull the sensor off the bracket NB Do not release the set screw 3 Screw the bracket using the screws supplied to the l...

Страница 7: ...1 Remove the set screw 2 Hold the function button in for 20 seconds The light beam will flash for 60 seconds 3 Rotate the sensor so the light beam hits the centre of the hob 4 Tighten the set screw at...

Страница 8: ...sh All connected units are now deleted Installation information Blue Yellow Red Green Programming button Green Lights up continuously while the relay is connected Flashes if there is no communication...

Страница 9: ...dio contact it will start to beep and the function test will run If the sensor does not have radio contact see Pairing page 11 NB After 2 minutes the function test will deactivate Remember to deactiva...

Страница 10: ...to Relay again for 5 seconds by turning the relevant protection circuit off and on NB This must be done within one minute of powering the relay under Point 2 or the pairing will not be saved 4 Set DI...

Страница 11: ...i 10 sek en gang til for g tilbake til 2 timer drift ett lydsignal OBS P se at du har nye batterier tilgjengelig Alarms signals with use of Mkomfy Alarm signal One 1 sound signal every 15 seconds Cau...

Страница 12: ...Mkomfy 2G R T 25A Chrome 6251662 Mkomfy 2G R T 25A Black 6251663 Mkomfy 2G R T 25A White Technical data Mkomfy Komfyrvakt R T 25A Voltage 230 VAC 10 Max load 25 A Physical dimensions sensor 83x32 mm T...

Отзывы: