FS301 Flame Simulator

 

FS301 Safety and Technical Manual

 

2

 

Ref: 2301.6042

 

Rev: 2.3 ECN: 4553

 

 

 

 

Safety Instructions 

1.1 

Warnings 

1.2 

Cautions 

1.3 

Important Notices 

Introduction 

2.1 

Features 

2.2 

Flame Simulator Enclosure 

Operating Instructions 

 

 

 

Maintenance and Testing 

4.1 

Routine 

4.2 

Battery Charging 

Fault Finding 

5.1 

Diagnostics 

5.2 

Replacement and Repair 

Technical Specification 

6.1 

Electrical Specification 

6.2 

Mechanical Specification 

6.3 

Environmental Specification 

6.4 

Certification and Approvals 

Appendix A

 

Help us to help you 

10 

Содержание 2301.6042

Страница 1: ...FS301 FLAME SIMULATOR SAFETY TECHNICAL MANUAL Ref 2301 6042 ECN 4431...

Страница 2: ...E OF This document is strictly private and confidential reproduction without Micropack approval is prohibited Micropack Engineering Ltd 2015 FS301 Flame Simulator FS301 Safety and Technical Manual 2 R...

Страница 3: ...attempt to replace the window as the glass and the front cover are individually matched pairs to meet the stringent requirement of the Hazardous area certification The threaded portions of the detecto...

Страница 4: ...r is a portable hand held unit designed for single operator operation Robust and Reliable The flame simulator has been designed for extreme offshore conditions Reduced Maintenance Costs Reduces the ne...

Страница 5: ...ng loaded and releasing the pressure from the switch will disconnect the power Charging Socket inside end cap Pushbutton The picture above shows the FS301 flame simulator The on off pushbutton is show...

Страница 6: ...n on charger unit Wait until charger LED is green The yellow button causes the charger unit to completely discharge the battery pack prior to re charging Unless this is done the battery pack will reta...

Страница 7: ...the flame simulator fails to operate there are two simple causes a b The flame simulator batteries need recharged or The unit is faulty and needs to be returned to Micropack 5 2 Replacement and Repai...

Страница 8: ...RH 0 100 Non Condensing Parameter Units Value Comment Enclosure Overall Dimensions mm 100 Diameter x 200 Length Shipping Weight Kg 2 5 Material LM25 Alloy Coating Colour Red Epoxy Coated Finish Pushb...

Страница 9: ...3 ECN 4553 Certification and Approvals Parameter Authority Standard Approval Certificate Hazardous Area Certification EN 60079 1 2014 Ex II 2 2 G Ex db op is T6 Gb IIC T6 Gb IP66 FM09ATEX0034 Explosi...

Страница 10: ...056 Email info micropack co uk From Tel Fax Email I suggest the following corrections changes be made to Section Marked up copies attached as appropriate Yes No Please inform me of the outcome of this...

Страница 11: ...4 0 1224 784056 Email sales micropack co uk micropack co uk In the Americas MICROPACK Detection Americas Inc 1227 Lakecrest Court Fort Collins Colorado 80526 Tel 1 970 377 2230 Fax 1 970 377 2273 Emai...