PF D550 Portable Doppler Flow Meter
SENSOR MOUNTING
Prepare an area 50mm x 100mm long (2" wide by 4") for sensor bonding by removing loose paint, scale
and rust. The objective of site preparation is to eliminate any discontinuity between the sensor and the
pipe wall, which would prevent acoustical coupling.
A PC4 Sensor Mounting Kit is supplied with each Micronics flow meter. It includes recommended
coupling compound in a plastic applicator and a stainless steel mounting bracket with adjustable pipe
straps.
15mm / 0.6”
4.5m / 180”
81cm / 32”