7
U K
6
U K
the display to clear.
NOTES
• If no further keys are pressed, the display will clear
(except for the battery level icon) and the backlight
will switch off, after 10 seconds
• To re-enter editing mode, simply press any direction
key.
• When changing nightlight settings, the nightlight will
NOT illuminate until the display clears and the
display backlight switches off. This is because the
display backlight is very much brighter than the
nightlight. In order to make nightlight setting more
convenient, the display will clear after only 2.5
seconds, when changing nightlight settings.
• When setting vibration sensitivity (RS1 only) and
nightlight brightness, the minimum level (1 bar)
switches the feature off entirely (i.e. there is no
“zero” setting)
ROLLERWHEEL SENSITIVITY FUNCTION
The rollerwheel sensitivity function allows the user to
select 8 different levels of sensitivity.
Minimum sensitivity (1 level bar showing), requires
the largest line movement to cause a trigger.
Maximum sensitivity (8 level bars showing) requires
the smallest line movement to cause a trigger.
The Micron RS1 & RS2 incorporate a “see-saw effect”
elimination feature - in all sensitivity settings (except
maximum), the line must travel the specified distance
in the same direction, in order to trigger the unit. Any
movement in the opposite direction will reset the dis-
tance counter to zero. This can substantially reduce,
or eliminate, false triggering caused by wind and
water movement.
Once the unit has been triggered, it automatically
switches to maximum sensitivity, irrespective of the
sensitivity setting, to accurately reflect a fast run.
Each icon will flash in turn, as it is selected. When the
required icon is flashing, press
on the navigation
switch, to edit the chosen setting. The display will
change to show the current level. As an example, the
following might be shown, if rollerwheel sensitivity was
selected –
In this example, 8 level bars are showing, so the
rollerwheel sensitivity is set to maximum.
To change a setting, simply use the
and
direc-
tions of the navigation switch, to increase or decrease
the number of bars showing.
When the desired level has been set, press
on
the navigation switch, to return to the default editing
screen . Other settings can now be selected and
altered as required. If the user does not wish to alter
any further settings, then there is no need to return
to the default editing screen. The display will clear
itself after 10 seconds.
AUDIBLE INDICATIONS
• When setting volume, a two-tone ascending or
descending tone will be heard at the new volume
setting, each time it is changed
• When setting tone, a single tone, at the new tone
setting, will be heard each time it is changed
• For all other parameters, a short high “click” will be
heard on each key press
• The bite alarm will continue to work as normal when
changing settings – i.e. the user can trigger the
rollerwheel or vibration sensor (RS1 only), to check
the effect of the new settings, without waiting for
Содержание RS-2