AVP
INSTRUCTIONS
E
12
SYSTEM CONFIGURATION (Continue)
Press on the Mode key again. The display
indicates now:
By using the rotary encoder, you will enter the
measured distance noted as DIM-F in the previous
chart.
Press on the mode key again and the display will
indicate:
The default value X.Xm is the value you had just
entered as the DIM-F value for your system. For
proper operation the Center speaker SHOULD NOT
BE more far away than the front left and right
speakers are but can be closer than these by a
maximum of 1.5m.
By using the rotary encoder, you will enter the
measured distance noted as DIM-C in the previous
chart. As explained this distance should vary between
DIM-F and DIM-F minus 1.5m.
Press on the Mode key again. The display
indicates now:
By using the rotary encoder, you will enter the
measured distance noted as DIM-RS in the previous
chart. For proper operation this distance should vary
between DIM-F and DIM-F minus 4.5m.
Press on the mode key again and the display will
indicate:
By using the rotary encoder, you will enter the
measured distance noted as DIM-LS in the previous
chart. For proper operation this distance should vary
between DIM-F and DIM-F minus 4.5m.
Press on the mode key again to enter the level
adjustment procedure.
The display now indicates:
SYSTEM LEVELS ADJUSTMENT
AVP incorporates a semi-automatic noise
sequencer that has been designed to make this
adjustment remarkably easy.
If you do not want to enter the Test then turn the
Rotary encoder to get NO and press the Mode key
again to revert to normal operation.
However, we strongly recommend that you enter
the Test procedure. Press on the MODE key and the
display will now indicate:
You can adjust now the level of the noise
sequencer until you reach the appropriate level for
your system. You will only be able to reach –10db, as
AVP will give you the possibility to adjust each
channel by
±
10db. Right after the correct level will
have been set a 2 seconds noise sequence on each
speaker starts by Front left, followed by Center and
going clockwise on each one of the speakers
according to your system configuration. The 2
seconds is the optimum value for the ear to remember
the last level and to perceive most accurately the level
difference between two channels.
Whenever you enter a different level on one
channel this new level will stay on for 2 seconds and
the sequence will then resume.
You can stop the automatic sequencer by a single
press on the Mode key. The sequencer stops where it
was and you have then the possibility to move from
channel to channel in clockwise mode by pressing on
the Mode key again.
The relative level of each channel is adjusted using
the Main
∆∇
keys on the remote control handset.
Once the perceived level from the center of the
viewing area is equal on all channels you may exit the
noise test sequence in pressing on the input key of
the remote control handset.
The display now indicates :
and after a few seconds:
AVP is now ready for normal operation.
F I< >I 3.0m
RS I< >I 1.5m
C I< >I X.Xm
LS I< >I 1.5m
TEST -30dB
CO1 - 30dB
CO1 UNLOC
TEST YES