Setting Dip 1 in ON position
Check and adjust the covering area (see the previuos diagramm)
Move into the protecting area and check the specific indicators (LED)
switching on.
Considering that the two infrared sensors are sensitive to the across and not to
the approach.
If the detection do not meet the own needs you will adjust the microwave
range by the trimmer ( to put up turning in an anticlockwise direction and to put
down turning in an clockwise direction) or you will adjust the sensor inclination
angle. N.B. When the microwave detect a movement too, the detector will
produce an alarm, the microwave is always turn off, it is activated with AND
mode if both the two infrared sensors detect an alarm. With OR mode if one of
the two infrared sensors detects an alarm.
INSTALLATION TIPS
WORKING/OPERATING TEST