Microlink 9448 Скачать руководство пользователя страница 7

DIP 2: ANTI MASK 
 
Setting the DIP 2 in OFF anti-masking disabled. 
Setting the DIP 2 in ON frontal anti-masking enabled by active infrared. 

NOTE: 

Open the detector, connect the power supply cables, close the detector 
and power it.  
Wait for 5 minutes for the stabilization of the system 
If obscure the field detection of the detector and the dip 2 is ON, in a 
maximum time of 10 seconds generates a tamper alarm (the output-mask 
open) and remains in alarm as long as it remains the cause  . 

 

DIP3: “AND” FUNCTION 
 
This  function  is  activated  setting  DIP  3  in  OFF  position.  In  this 
configuration,  when  the  two  infrared  sensors  and  the  microwave  sensor 
detect  a  movement,  the  detector,  will  trigger  an  alarm.  This  mode  is 
recommended  in  external  environments  with  unstable  elements  may 
cause a false alarm.  

 

 
DIP 3: “OR” FUNCTION 
 
This mode is activated setting DIP 3 in ON position. In this configuration, 
when one of the two infrared sensors and the microwave sensor detect a 
movement,  the  detector  will  produce  an  alarm.  It  is  recommended  in 
completely external environments and in presence of small animals. 
With this mode every small movement is detected. 

 

 

DIP 4: MICROWAVE DE-ACTIVATION 
 
DIP 4 in  OFF.  

Microwave enabled. 

DIP 4 in  ON .   

Microwave disabled. 

 
This mode refers to the microwave alarm detection. 
In particularly narrow environments ( such as garage passages, gardens 
pedestrian  areas)  it  is  reccommended  setting  DIP  4  in  On  position  in 
order  to  have  the  infrared  sensors  detection  only.  If  you  use  this  mode, 
you will always set DIP 3 in Off position (AND mode). 

 

 

 
 
 

 

Содержание 9448

Страница 1: ...MADE IN ITALY...

Страница 2: ...AND OR Power supply From 10 5 to 14 VDC Power consumption Standby di 1 5 mA Max power consumption 12 mA X 4 SEC Relay contact NC 100mA MW range adjustment By trimmer Alarm time 1 2 sec Light indicator...

Страница 3: ...Led Indicator Tamper Microwave Adjustement Dip switch PIR 1 PIR 2 PIR 2 Adjustement screw Terminal Block Antimasking Led...

Страница 4: ...RAM Configuration AND position A B C Configuration OR1 Configuration OR 2 position A Configuration OR 2 position B Configuration OR 2 position C Detection plan view The microwave detection covering ar...

Страница 5: ...DETECTION Configuration AND position A Configuration AND position B Configuration AND position C...

Страница 6: ...ors are sensitive to rapid temperature changes Avoid to direct the sensor towards the sun point the sensor directly to the sun In presence of animals adjust the detection angle rightly The detector ha...

Страница 7: ...ill trigger an alarm This mode is recommended in external environments with unstable elements may cause a false alarm DIP 3 OR FUNCTION This mode is activated setting DIP 3 in ON position In this conf...

Страница 8: ...needs you will adjust the microwave range by the trimmer to put up turning in an anticlockwise direction and to put down turning in an clockwise direction or you will adjust the sensor inclination an...

Страница 9: ...Caution Take note In presence of hedges or bushes cover the beams infrared lens corresponding to the plants like in the figure...

Отзывы: