TECHNICAL SPECIFICATIONS

 

 

Installation on the wall 

Coverage 15 mt, angle 90° 

Frequency microwave 

10.525 GHz 

Alarm technology 

DSP(Digital Signal Processing) 

Detecting distance 

From  3 to 15 mt 

Detection areas 

8 aeras for each sensor 

Installation height 

0,8-1,4 m (reccomended 1mt) 

Detecting mode 

Selectable: AND-OR 

Power supply 

From  10,5  to 14 VDC  

Power consumption 

Standby < di 1.5 mA 

Max power consumption 

12 mA X 4 SEC 

Relay contact 
 

NC 100mA 
 

MW range adjustment 

By  trimmer 

Alarm time 

 1,2 sec 

Light indicators 

LEFT RED : IR UPPER  
RIGHT RED : IR LOWER 
YELLOW : MICROWAVE  
  

Detecting speed  

 from 0.2 to 3.5 m/s 

RFI/EMI  immunity 

3 V/m between 0.1MHz-500MHz 

Light immunity 

>10000 Lux 

Programming 

by dip Switch 

Operating temperature 

From  -10°C  to  +55° C 

Protection rating 

IP54 

 
DESCRIPTION 

 
 
  

 

   
 
 

    Cover 

Closing 
screw 

Electronic 
part 
 

Содержание 9448

Страница 1: ...MADE IN ITALY...

Страница 2: ...AND OR Power supply From 10 5 to 14 VDC Power consumption Standby di 1 5 mA Max power consumption 12 mA X 4 SEC Relay contact NC 100mA MW range adjustment By trimmer Alarm time 1 2 sec Light indicator...

Страница 3: ...Led Indicator Tamper Microwave Adjustement Dip switch PIR 1 PIR 2 PIR 2 Adjustement screw Terminal Block Antimasking Led...

Страница 4: ...RAM Configuration AND position A B C Configuration OR1 Configuration OR 2 position A Configuration OR 2 position B Configuration OR 2 position C Detection plan view The microwave detection covering ar...

Страница 5: ...DETECTION Configuration AND position A Configuration AND position B Configuration AND position C...

Страница 6: ...ors are sensitive to rapid temperature changes Avoid to direct the sensor towards the sun point the sensor directly to the sun In presence of animals adjust the detection angle rightly The detector ha...

Страница 7: ...ill trigger an alarm This mode is recommended in external environments with unstable elements may cause a false alarm DIP 3 OR FUNCTION This mode is activated setting DIP 3 in ON position In this conf...

Страница 8: ...needs you will adjust the microwave range by the trimmer to put up turning in an anticlockwise direction and to put down turning in an clockwise direction or you will adjust the sensor inclination an...

Страница 9: ...Caution Take note In presence of hedges or bushes cover the beams infrared lens corresponding to the plants like in the figure...

Отзывы: