Power up Sequence:
Required:
• -48/+24VDC power source with the included power cable. Follow wiring diagram shown
• OR use the Microlab
GPSA003
AC/DC power supply (not included)
1. Carefully align and mate the power cable M12 Female connector to the remote unit’s
Power
M12 Male
Receptacle
2. Turn on DC power source or plug-in the Microlab
GPSA003
to the 100-240VAC outlet.
- If the remote unit is deployed with the power supply, both LEDs will illuminate.
- Off Status LEDs indicate that power supply is not functioning or not connected.
Note: Bootup time is approximatelly 60 seconds. During this time both front panel LEDs will be
Yellow
.
After system bootup, LEDs will illuminate
RED
while waiting for GPS signal lock and Fiber Link connection.
Microlab, A Wireless Telecom Group Company, 25 Eastmans Road, Parsippany, NJ 07054
Tel: (973) 386-9696 • [email protected] • www.microlabtech.com • Fax: (973) 386-9191
GPSR400 Quick Start Guide
US Model, 4-Channel Remote Outdoor Unit
page 6
Connecting Power
-48/+24 VDC
Connect DC Positive and Negative
terminals as follow:
1. Brown
/
Positive
(+)
2 White
/
Positive
(+)
4. Black
/
Negative
(-)
3. Blue
/
Negative
(-)
Power Cable (Part#: 1-2273029-1)