SAFETY NOTE: When replacing the fuse, be sure to disconnect power from the AC wall outlet. 

 

 
KEYPAD LCD DISPLAY 
The Model 910 keypad has its own built-in, easy-to-read display so that you can see what numbers are being entered, as 
well as what numbers are currently being shown on the Visual-Pager® display. 
 
 
 
 
 
 
The status of the keypad is shown in the upper left corner of the keypad display.  Here are the different statuses you will 
see: 

“Ready” – Normal Operation 
“Enter” – Adding a Number 
“Delete” – Removing a Number 
“FULL” – The number list is full 

The numbers just below the status designation show what numbers you are currently entering.  In this case, the number 
“78901” is being entered. 
The numbers in the upper right corner show what numbers are currently being shown on the Visual-Pager® display.  In 
this case, the number “123456” is being shown. 
 
ENTER MODE 
When  a  number  button  is  pressed,  the  keypad  will  go  into  Enter  Mode.    The  "ENTER"  light  will  flash,  and  the  keypad 
display will show “Enter” in the top left corner.  The number currently on the Visual-Pager® display will continue to show 
in the upper right corner of the keypad display while the number you are entering will show in the lower left-hand corner 
of the keypad display.  Continue to type number buttons until the complete  number to be paged is shown.  Then press 
[ENTER] to display the paging number on the Visual-Pager® display.  When [ENTER] is pressed, the new number will be 
placed in sequence with any other numbers displayed on the Visual-Pager display.  If you make an error while typing a 
number, press [DELETE.]  If you attempt to enter over thirty-two numbers into the system, the Master Keypad "Ready" 
message will change to "Full" until a number is deleted.  
 
DELETE MODE 
To  delete  a  number,  press  [DELETE]  twice  when  that  number  appears  on  the  keypad  display.    The  next  available 
number  will  be  displayed  immediately.    You  may  also  delete  a  number  by  pressing  [DELETE],  typing  the  number,  and 
pressing [DELETE] again.  If you make an error while deleting a number, press [ENTER]. 
 
MULTIPLE OUTPUTS 
The keypad will power multiple Visual-Pager® displays.  Please see the Maximum Cable/Wire Length Table. 
 
MULTIPLE INPUTS 
You may cascade up to thirty-two numbers on the same common cable connected to the "Signal Out" output from each 
keypad.    Numbers  entered  from  each  keypad  will  automatically  be  combined  and  displayed  in  sequence  with  all  the 
numbers entered from all keypads.  Each keypad will display all numbers entered from it as well as all numbers entered 
from all other keypads- at the same time they are displayed on the Visual-Pager® display(s).  
Note:  Keypads must be programmed as the same keypad type to work together. 
 
POWER CONNECTION 
Connect the wall mount transformer to an AC outlet, and then connect the power plug to the connector on the top of the 
keypad marked "18-24 VAC."  It is recommended that you turn the power off using the "ON/OFF" switch on the keypad 
when not in use. This will greatly prolong the life of the system. 
 
FUSE 
The keypad contains a fuse inside the case under the small slide-on cover.  To prevent permanent damage, replace with 
the correct fuse.  For standard keypads use a 1.6A (5mmx20mm) fast acting fuse.  For keypads with a 2.5A adapter, use 
a 2.5A (5mmx20mm) fast acting fuse. 
 
 
 
OPTION CONNECTIONS 
The keypad has two optional connections on the 8-pin terminal block located under the small removable cover: 

1. AUX—Auxiliary connection for use with the extra cost Remote Delete Option. 
2. A/C—Remote 24 VAC Input used when a adapter other than the wall mounted one supplied with the system 
is required, such as an attic-mounted adapter installation. 

Note: Each keypad must operate off its own power adapter.  Keypads cannot share power adapters. 

Keypad Operation 

Содержание 910

Страница 1: ... Street Broken Arrow OK 74012 Local 918 258 4839 Toll Free 800 635 3811 Website www microframecorp com E mail support microframecorp com SERIES 900 INSTALLATION and SPECIFICATION GUIDE Manual No D0910 7010 Revision Date 09 2013 Control 1 6 D0910 7010 ...

Страница 2: ...ust use plenum rated cable The cable supplied from Microframe is rated CL2 and is approved for indoor installation everywhere except plenum areas Life Support Policy Microframe s products are not authorized for use as components in life support devices or systems without the express written approval of the President of Microframe Corporation As used herein 1 Life support devices or systems are def...

Страница 3: ...pecificationGuide Table of Contents Series 900 System Overview and Features 4 System Installation Instructions 5 Maximum Cable Wire Length Chart 6 How to Connect Multiple Keypads to a Display 7 How to Connect a Display to a Keypad 8 Keypad Operation 9 Keypad Options 10 Visual Pager Display Operation 11 Error Codes and Troubleshooting Chart 12 ...

Страница 4: ...e Rollover Time Automatic Delete and Manual Advance Once a number is entered into the Keypad the number is sent immediately to the Visual Pager Display The keypad will store up to 32 numbers and display them sequentially until the operator deletes them In 4 digit mode the keypad will show numbers from 0 to 9999 This mode is compatible with Model 920 930 and 940 displays In 6 digit mode the keypad ...

Страница 5: ...ounted at eye level However it may also be placed on a desk Multiple keypads may be used on the same system and will automatically communicate with each other when wired together KEYPAD CONNECTION Unplug the keypad before continuing Slide off the back cover of the keypad and connect the 2 conductor wire Connect the black wire to GND and the red wire to SIG There are two terminals for both GND and ...

Страница 6: ...ly use 16 AWG wire from the keypad You can now install four Model 960 6 digit displays up to 1 200 feet from the keypad The TOTAL CABLE LENGTH sum of length of all cables in the system should not exceed 10 000 feet Maximum Cable Wire Distance in Feet Model 920 Model 930 Model 940 Model 960 Number of Displays 18 AWG 16 AWG 18 AWG 16 AWG 18 AWG 16 AWG 18 AWG 16 AWG 1 2000 2000 2000 2000 2000 2000 20...

Страница 7: ...ELETE when the number is being displa yed 2 Ready123456 115 TO 24 VAC WALL MOUNTED TRANSFORMER Model 906 Model 910 K eypad ENTER 0 DELETE 1 3 4 5 6 7 8 9 Visual P ager Series 900 To ENTER a paging n umber type its digits press DELETE if an error is made Then press ENTER A Blinking light indicates a n umber is being entered To DELETE a paging n umber press DELETE when the number is being displa yed...

Страница 8: ...Y AUX AUX AUX AUX NEX T DISPL AY ORKEY PAD STEP 1 Remove slide on cover from back of keypad STEP 2 Remove 1 5 of gray jacket from wire and separate the internal wires Strip 1 4 of insulation from each wire and pre form as shown STEP 3 Insert black wire into one of the GND terminals Insert red wire into one of the SIG terminals Tighten terminal screws STEP 4 IF REQUIRED If a second set of wires are...

Страница 9: ...deleted DELETE MODE To delete a number press DELETE twice when that number appears on the keypad display The next available number will be displayed immediately You may also delete a number by pressing DELETE typing the number and pressing DELETE again If you make an error while deleting a number press ENTER MULTIPLE OUTPUTS The keypad will power multiple Visual Pager displays Please see the Maxim...

Страница 10: ...ff On Default 1 The audible feedback sound can be enabled or disabled 14 Chime 0 0 9 9 Seconds Default 0 3 Sets the Visual Pager display chime duration Not all displays follow this option 19 Factory Reset 0 1 No Yes Resets all options to factory defaults 21 MastSlave 0 2 Auto Master Slave Default 0 This controls the master slave arbitration on a system There should only be one master on a system A...

Страница 11: ...to 6 digit numbers Compatible with Model 960 Displays HYMNBOARD MODE If the user would like to use the keypad to show hymn numbers in a song service the following steps should be taken 1 Program the Rollover Time 1 1 to 0 2 Program the Sort Option 2 3 to 0 3 Program the DeleteKey Option to 2 After these options have been programmed enter the hymn numbers in the order in which they will be displaye...

Страница 12: ... Keypad cannot remember settings Keypad is damaged Return for service Keypad displays CommErr Communication error Verify programming to make sure only one keypad is a master Check wiring between keypads Check for strong interference next to signal cable Keypad works but does not light up or has erratic numbers Poor signal connection to display Does the keypad work when connected to the display wit...

Отзывы: