Microframe Corporation 910 Скачать руководство пользователя страница 6

 

 

 

Microframe Corporation 

 

 

 

 

 

 

 

6

 

604 South 12

th

 Street 

Broken Arrow, OK  74012 
800-635-3811 
www.microframecorp.com 

 

 

 

 

 

 

Series 900 

 
 
 
The  following  chart  shows  the  maximum  number  of  displays  that  can  be  installed  per  cable/wire  length 
indicated.    The  cable/wire  length  can  be  increased  by  simply  putting  fewer  displays  on  EACH  CABLE 
connected to the Model 910 Keypad.  For example, when using 18 AWG wire, you can install a maximum of 
four Model 960 (6-digit) Visual-Pager® displays up to 700 feet from the keypad on a single cable.  However, 
if a greater distance is required, simply use 16 AWG wire from the keypad.  You can now install four Model 
960 (6-digit) displays up to 1,200 feet from the keypad.  The TOTAL CABLE LENGTH (sum of length of all 
cables in the system) should not exceed 10,000 feet. 

Maximum Cable/Wire Distance in Feet 

Model 920 

Model 930 

Model 940 

Model 960 

Number of 

Displays 

18 

AWG 

16 

AWG 

18 

AWG 

16 

AWG 

18 

AWG 

16 

AWG 

18 

AWG 

16 

AWG 

2000 

2000 

2000 

2000 

2000 

2000 

2000 

2000 

2000 

2000 

2000 

2000 

1500 

2000 

800 

1300 

2000 

2000 

1300 

2000 

800 

1300 

500 

700 

1500 

2000 

900 

1300 

600 

900 

300 

400 

1100 

1500 

600 

900 

400 

600 

100 

200 

800 

1300 

400 

700 

300 

400 

  

100 

600 

1100 

300 

500 

200 

300 

  

  

500 

800 

200 

400 

100 

200 

  

  

400 

700 

200 

300 

  

100 

  

  

10 

300 

500 

100 

200 

  

  

  

  

11 

300 

400 

100 

100 

  

  

  

  

12 

200 

400 

NA 

100 

  

  

  

  

Maximum Cable/Wire Length Chart

 

Содержание 910

Страница 1: ... Street Broken Arrow OK 74012 Local 918 258 4839 Toll Free 800 635 3811 Website www microframecorp com E mail support microframecorp com SERIES 900 INSTALLATION and SPECIFICATION GUIDE Manual No D0910 7010 Revision Date 09 2013 Control 1 6 D0910 7010 ...

Страница 2: ...ust use plenum rated cable The cable supplied from Microframe is rated CL2 and is approved for indoor installation everywhere except plenum areas Life Support Policy Microframe s products are not authorized for use as components in life support devices or systems without the express written approval of the President of Microframe Corporation As used herein 1 Life support devices or systems are def...

Страница 3: ...pecificationGuide Table of Contents Series 900 System Overview and Features 4 System Installation Instructions 5 Maximum Cable Wire Length Chart 6 How to Connect Multiple Keypads to a Display 7 How to Connect a Display to a Keypad 8 Keypad Operation 9 Keypad Options 10 Visual Pager Display Operation 11 Error Codes and Troubleshooting Chart 12 ...

Страница 4: ...e Rollover Time Automatic Delete and Manual Advance Once a number is entered into the Keypad the number is sent immediately to the Visual Pager Display The keypad will store up to 32 numbers and display them sequentially until the operator deletes them In 4 digit mode the keypad will show numbers from 0 to 9999 This mode is compatible with Model 920 930 and 940 displays In 6 digit mode the keypad ...

Страница 5: ...ounted at eye level However it may also be placed on a desk Multiple keypads may be used on the same system and will automatically communicate with each other when wired together KEYPAD CONNECTION Unplug the keypad before continuing Slide off the back cover of the keypad and connect the 2 conductor wire Connect the black wire to GND and the red wire to SIG There are two terminals for both GND and ...

Страница 6: ...ly use 16 AWG wire from the keypad You can now install four Model 960 6 digit displays up to 1 200 feet from the keypad The TOTAL CABLE LENGTH sum of length of all cables in the system should not exceed 10 000 feet Maximum Cable Wire Distance in Feet Model 920 Model 930 Model 940 Model 960 Number of Displays 18 AWG 16 AWG 18 AWG 16 AWG 18 AWG 16 AWG 18 AWG 16 AWG 1 2000 2000 2000 2000 2000 2000 20...

Страница 7: ...ELETE when the number is being displa yed 2 Ready123456 115 TO 24 VAC WALL MOUNTED TRANSFORMER Model 906 Model 910 K eypad ENTER 0 DELETE 1 3 4 5 6 7 8 9 Visual P ager Series 900 To ENTER a paging n umber type its digits press DELETE if an error is made Then press ENTER A Blinking light indicates a n umber is being entered To DELETE a paging n umber press DELETE when the number is being displa yed...

Страница 8: ...Y AUX AUX AUX AUX NEX T DISPL AY ORKEY PAD STEP 1 Remove slide on cover from back of keypad STEP 2 Remove 1 5 of gray jacket from wire and separate the internal wires Strip 1 4 of insulation from each wire and pre form as shown STEP 3 Insert black wire into one of the GND terminals Insert red wire into one of the SIG terminals Tighten terminal screws STEP 4 IF REQUIRED If a second set of wires are...

Страница 9: ...deleted DELETE MODE To delete a number press DELETE twice when that number appears on the keypad display The next available number will be displayed immediately You may also delete a number by pressing DELETE typing the number and pressing DELETE again If you make an error while deleting a number press ENTER MULTIPLE OUTPUTS The keypad will power multiple Visual Pager displays Please see the Maxim...

Страница 10: ...ff On Default 1 The audible feedback sound can be enabled or disabled 14 Chime 0 0 9 9 Seconds Default 0 3 Sets the Visual Pager display chime duration Not all displays follow this option 19 Factory Reset 0 1 No Yes Resets all options to factory defaults 21 MastSlave 0 2 Auto Master Slave Default 0 This controls the master slave arbitration on a system There should only be one master on a system A...

Страница 11: ...to 6 digit numbers Compatible with Model 960 Displays HYMNBOARD MODE If the user would like to use the keypad to show hymn numbers in a song service the following steps should be taken 1 Program the Rollover Time 1 1 to 0 2 Program the Sort Option 2 3 to 0 3 Program the DeleteKey Option to 2 After these options have been programmed enter the hymn numbers in the order in which they will be displaye...

Страница 12: ... Keypad cannot remember settings Keypad is damaged Return for service Keypad displays CommErr Communication error Verify programming to make sure only one keypad is a master Check wiring between keypads Check for strong interference next to signal cable Keypad works but does not light up or has erratic numbers Poor signal connection to display Does the keypad work when connected to the display wit...

Отзывы: