Series 900 

CAUTION: be careful not to connect to the AUX or AC terminals.  The AC terminals are used as an 
alternate connection point for power.  This is only used with power adapters that have bare wires 
instead of a plug.   

 
 
 

INTRODUCTION 
 
Save yourself some work - review these instructions before starting installation. 
 
This  Keypad  is  configured  to  work  with  2,  3,  and  4-digit  displays.    For  6-digit  displays  change  the  option 
"Keypad Type" to six digit mode.  See Option 2.7 in Section 3, "Keypad Options". 
 
PRE-INSTALLATION 
We recommend  testing  the system  before  installation.    Connect  the  keypads  and  displays  together  in  one 
room.    Once  you  are  satisfied  that  the  system  is  working,  proceed  with  your  cable  runs  and  equipment 
mounting. 
 
CABLE INSTALLATION 
A single cable carries both power and signal from the keypad to the displays.  RCA cable may be used, but 
most  installers  find  it  easier  to  work  with  2-conductor,  18AWG  wire.    Use  16AWG  wire  to  improve  the 
maximum distance.  Unshielded cable is acceptable.  CAT 5/6 cable is not recommended, as the small wires 
tend to break at the keypad.  For aesthetic reasons, the installer may want to hide the cable to the displays.  
This can be accomplished by punching holes in the wall directly behind the displays.  See “Remote Display 
Mounting Template”.  To support additional displays or longer cable runs than the Keypad can handle, use 
Booster Amp Model A0160. 
 
KEYPAD INSTALLATION 
 The  Keypad  is  typically  wall-mounted  at  eye  level.    However,  it  may  also  be  placed  on  a  desk.    Multiple 
keypads may be used on the same system, and will automatically communicate with each other when wired 
together. 
 
KEYPAD CONNECTION 
Unplug the keypad before continuing.  Slide off the back cover of the keypad and connect the 2-conductor 
wire.  Connect the black wire to “GND” and the red wire to “SIG.”  There are two terminals for both “GND” 
and “SIG,” allowing for two sets of wires to be connected.   
 
 
 
 
Once the wires are firmly connected, slide the protective cover back on and place the Keypad back into the 
holder. 
 
DISPLAY INSTALLATION 
The display will have optimum visibility when mounted vertically within three to four feet of eye level.  This 
will  keep  the  display  in  the  proper  field  of  view  for  the  observer.    To  hang  a  display  on  the  wall,  place  an 
anchor screw into the wall, leaving the screw-head exposed.  Line up the keyhole on the back of the display 
with the screw.  Hang the display from the screw.  The “Display Mounting Template” provides a guide to line 
up the mounting screw(s). 
 
DISPLAY CONNECTION 
Wire is fed from the wall through the cutouts on the back of the display.  Connect the black wire to “GND” 
and the red wire  to “SIG.”   The additional  terminals allow a parallel set  of wires to carry power to the  next 
display.  Once the wires are firmly connected, hang the display back on the mounting screw(s). 
 
TESTING THE SYSTEM 
Once the system is wired together, plug in the keypad and turn it on.  If the keypad shows “SHORT”, then 
there  is  a  short  in  the  wiring.    Turn  off  the  keypad  and  check  the  wiring.    Otherwise,  type  “123”,  press 
“ENTER”, and verify that “123” shows on all the displays.  See the “Troubleshooting Chart” at the end of this 
manual for additional assistance. 

Installation Instructions

 

Содержание 910

Страница 1: ... Street Broken Arrow OK 74012 Local 918 258 4839 Toll Free 800 635 3811 Website www microframecorp com E mail support microframecorp com SERIES 900 INSTALLATION and SPECIFICATION GUIDE Manual No D0910 7010 Revision Date 09 2013 Control 1 6 D0910 7010 ...

Страница 2: ...ust use plenum rated cable The cable supplied from Microframe is rated CL2 and is approved for indoor installation everywhere except plenum areas Life Support Policy Microframe s products are not authorized for use as components in life support devices or systems without the express written approval of the President of Microframe Corporation As used herein 1 Life support devices or systems are def...

Страница 3: ...pecificationGuide Table of Contents Series 900 System Overview and Features 4 System Installation Instructions 5 Maximum Cable Wire Length Chart 6 How to Connect Multiple Keypads to a Display 7 How to Connect a Display to a Keypad 8 Keypad Operation 9 Keypad Options 10 Visual Pager Display Operation 11 Error Codes and Troubleshooting Chart 12 ...

Страница 4: ...e Rollover Time Automatic Delete and Manual Advance Once a number is entered into the Keypad the number is sent immediately to the Visual Pager Display The keypad will store up to 32 numbers and display them sequentially until the operator deletes them In 4 digit mode the keypad will show numbers from 0 to 9999 This mode is compatible with Model 920 930 and 940 displays In 6 digit mode the keypad ...

Страница 5: ...ounted at eye level However it may also be placed on a desk Multiple keypads may be used on the same system and will automatically communicate with each other when wired together KEYPAD CONNECTION Unplug the keypad before continuing Slide off the back cover of the keypad and connect the 2 conductor wire Connect the black wire to GND and the red wire to SIG There are two terminals for both GND and ...

Страница 6: ...ly use 16 AWG wire from the keypad You can now install four Model 960 6 digit displays up to 1 200 feet from the keypad The TOTAL CABLE LENGTH sum of length of all cables in the system should not exceed 10 000 feet Maximum Cable Wire Distance in Feet Model 920 Model 930 Model 940 Model 960 Number of Displays 18 AWG 16 AWG 18 AWG 16 AWG 18 AWG 16 AWG 18 AWG 16 AWG 1 2000 2000 2000 2000 2000 2000 20...

Страница 7: ...ELETE when the number is being displa yed 2 Ready123456 115 TO 24 VAC WALL MOUNTED TRANSFORMER Model 906 Model 910 K eypad ENTER 0 DELETE 1 3 4 5 6 7 8 9 Visual P ager Series 900 To ENTER a paging n umber type its digits press DELETE if an error is made Then press ENTER A Blinking light indicates a n umber is being entered To DELETE a paging n umber press DELETE when the number is being displa yed...

Страница 8: ...Y AUX AUX AUX AUX NEX T DISPL AY ORKEY PAD STEP 1 Remove slide on cover from back of keypad STEP 2 Remove 1 5 of gray jacket from wire and separate the internal wires Strip 1 4 of insulation from each wire and pre form as shown STEP 3 Insert black wire into one of the GND terminals Insert red wire into one of the SIG terminals Tighten terminal screws STEP 4 IF REQUIRED If a second set of wires are...

Страница 9: ...deleted DELETE MODE To delete a number press DELETE twice when that number appears on the keypad display The next available number will be displayed immediately You may also delete a number by pressing DELETE typing the number and pressing DELETE again If you make an error while deleting a number press ENTER MULTIPLE OUTPUTS The keypad will power multiple Visual Pager displays Please see the Maxim...

Страница 10: ...ff On Default 1 The audible feedback sound can be enabled or disabled 14 Chime 0 0 9 9 Seconds Default 0 3 Sets the Visual Pager display chime duration Not all displays follow this option 19 Factory Reset 0 1 No Yes Resets all options to factory defaults 21 MastSlave 0 2 Auto Master Slave Default 0 This controls the master slave arbitration on a system There should only be one master on a system A...

Страница 11: ...to 6 digit numbers Compatible with Model 960 Displays HYMNBOARD MODE If the user would like to use the keypad to show hymn numbers in a song service the following steps should be taken 1 Program the Rollover Time 1 1 to 0 2 Program the Sort Option 2 3 to 0 3 Program the DeleteKey Option to 2 After these options have been programmed enter the hymn numbers in the order in which they will be displaye...

Страница 12: ... Keypad cannot remember settings Keypad is damaged Return for service Keypad displays CommErr Communication error Verify programming to make sure only one keypad is a master Check wiring between keypads Check for strong interference next to signal cable Keypad works but does not light up or has erratic numbers Poor signal connection to display Does the keypad work when connected to the display wit...

Отзывы: