4  SYSTEM OVERVIEW

4.1 DESCRIPTION

The Datapage Lite is a desktop transmit-

ter that can be used to transmit to up to 9999 
coasters.  This transmitter can also transmit an 
out of range signal.  If enabled, when coasters 
are out of range of the transmitter they play a 
melody (ie sing).

4.2 RANGE EXPANSION

The range and performance of this equip-

ment can be improved by the addition of more 
effi cient antennas.* These can be installed 
either inside or outside the building and are 
connected to the transmitter with 50 OHM 
coaxial cable. 

The center-fed half wave dipole, measuring 

approximately 12 inches from tip to tip, will 
provide excellent all round local signalling.  It 
is a light duty antenna suitable for sheltered 
environments/internal installation (LUHFDP).  
It includes a 15 foot cable.

NOTE: High frequencies can equate to 

high power losses. Always use quality cable. 
RG58 is only acceptable on cable runs of up to 
5 meters (16.4 feet.) We recommend RG213, 
or equivalent, on greater lengths. If in doubt 
consult your dealer.

*Subject to license conditions. Specifi cally, 

mounting height and Effective Radiated Power 
(ERP)

.

4.3 IMPORTANT INFORMATION

It is the purchaser's responsibility to deter-

mine the suitability of this equipment and its 
derivatives for any given application.

Good working practice dictates that a suit-

able system installation log must be generated, 
together with a record of the dates when the 
system has been manually checked, (with the 
aid of signal strength meters, etc.) enabling the 
system performance to be compared with the 
original installation data.

4.4 SAFETY INFORMATION

These products are designed to operate 

safely when installed and used according to 
general safety practices.  The following require-
ments should be observed at all times:

Do NOT subject this equipment to:

Mechanical shock
Excessive humidity or moisture
Extremes of temperature
Corrosive liquids

This equipment is designed for indoor use, 

unless expressly stated otherwise, and must 
not be used in classifi ed  Hazardous Areas, 
including areas containing explosive or fl am-
mable vapors, unless express authorization has 
been given in writing by the manufacturer.  If 
in doubt, consult your local product dealer for 
further information.

Do not obstruct any slots or openings in the 

product.  These are provided for ventilation to 
ensure reliable operation of the product and to 
protect it from overheating.

4.5 CARING FOR TRANSMITTER

Only use a damp cloth for cleaning (not 

liquid or aerosol-based cleaners), and ensure 
that any power is removed from the unit prior 
to beginning the cleaning operation.

Removal of covers from the equipment must 

only be undertaken by authorized service per-
sonnel, who must ensure that power is isolated 
prior to removal.

4.6 LIABILITY

Scope and Microframe do not accept liability 

for any damage or injury caused as the result of 
misuse of this equipment. It is the responsibility 
of the user to ensure that the equipment is oper-
ated in the manner for which it was intended, 
and that it is the correct item of equipment for 
the required task.

4.7 WARRANTY INVALIDATION

Alteration or modifi cation to any part of this 

equipment, without the prior written consent 
of the manufacturer, will invalidate all manu-
facturer approvals and warranties.  No adjust-
ments can be undertaken except by qualifi ed 
and licensed persons as defi ned by the FCC 
Rules and Regulations. Operation of altered 
equipment can result in fi nes, imprisonment, 
and/or confi scation of such equipment.

4.8 SERVICE INFORMATION

If you experience a problem with your 

equipment, please contact Microframe at 1-
800-635-3811.

Содержание 3400 Series

Страница 1: ...Microframe Corporation Series 3400 Coaster Call Paging System Operating Manual B3400 7012 B3400 7012 ...

Страница 2: ...INSTALLATION SPECIFICATION GUIDE ITEM NO A3400 7012 REVISION DATE 11 09 Microframe Corporation 604 S 12th Street Broken Arrow OK 74012 Tel 918 258 4839 Toll Free 1 800 635 3811 Website www microframecorp com E mail support microframecorp com ...

Страница 3: ... microframecorp com Safety Do not install substitute parts or perform any modification to the product without first contacting Microframe Warning All power transformers line cords and electrical equipment should be kept out of the reach of children and away from water Life Support Policy Microframe s products are not autho rizedforuseascomponentsinlifesupport devices or systems without the express...

Страница 4: ...UP COASTERS 8 3 OPERATION 9 3 1 HANDING OUT COASTERS 9 3 2 PAGING THE GUEST 9 3 3 OUT OF RANGE FEATURE 9 3 4 CHANGING THE ALERT MODE 9 3 5 AUTO LOCATE FEATURE 9 4 SYSTEM OVERVIEW 10 4 1 DESCRIPTION 10 4 2 RANGE EXPANSION 10 4 3 IMPORTANT INFORMATION 10 4 4 SAFETY INFORMATION 10 4 5 CARING FOR TRANSMITTER 10 4 6 LIABILITY 10 4 7 WARRANTY INVALIDATION 10 4 8 SERVICE INFORMATION 10 MINI DIPOLE ANTENN...

Страница 5: ... out of range the moment they step out by continuously playing a melody until the mo ment they step back in This feature helps reduce the number of missed pages as well as accidental coaster walk outs Coasters are rechargeable and will last approximately 3 5 years before replacement of the battery is necessary Operation The transmitter and charging base simply plug into an outlet using the power a...

Страница 6: ... The flashing cursor invites you to enter a pagernumber thiscanbeanynumberbetween 1 and 9 999 after which you must press SEND to transmit a page See OPERATION page 9 for further transmitting procedures IMPORTANT NOTE Use only the power supply provided with your system The use of non approved power supplies will invalidate all war ranty and service We also recommend using a surge suppressor for pro...

Страница 7: ...rical cord into a standard 110 outlet 2 2 SETTING UP COASTERS Stack the coasters on the black charging base The coaster number will always face the front and the red charge indicator light will be on the left We recommend that you do not stack coasters more than 15 high as damage to the charger base may occur A red light should appear on each coaster to indicate proper charging The supplied 12v AC...

Страница 8: ...tter After 30 seconds all the coasters will play a melody since they are not receiv ing a signal from the transmitter Return all the coasters to the charging base or plug the power supply back in The coasters are ready to receive a page with the Out of Range feature turned on Follow the same procedure as above to turn off the Out of Range feature using the code 9393 instead of 9494 3 OPERATION 3 4...

Страница 9: ...led and used according to generalsafetypractices Thefollowingrequire ments should be observed at all times Do NOT subject this equipment to Mechanical shock Excessive humidity or moisture Extremes of temperature Corrosive liquids This equipment is designed for indoor use unless expressly stated otherwise and must not be used in classified Hazardous Areas including areas containing explosive or fla...

Страница 10: ...towards the ground Avoid mounting the dipole on or near to any metal girders pilars or other metallic obstructions The dipole should preferably be mounted at a height which avoids potential snagging with any moveable objects that might be used in the vicinity e g ladders Ensure that the bracket is firmly bolted to a solid suf ace and that the feeder cable is adequately clamped along it s entire ru...

Страница 11: ...rporation Series 3400 Coaster Call Paging System Microframe Corporation 604 S 12th Street Broken Arrow OK 74012 Tel 918 258 4839 Toll Free 1 800 635 3811 Website www microframecorp com E mail support microframecorp com ...

Отзывы: